ENGINEERS MANUAL
CST MACHINES AND DRYER UNIT
Drawn up: 05/10/2018
Document number : 30008893
Page 15 of 48
Revision: C
Machine temperature settings:
The water temperatures on
’
Classeq
’ range of machines are adjustable, but have been pre-set to:
Thermostat positions
Rinse thermostat
–
standby (ST1)
Rinse thermostat
–
Running (ST2)
Wash thermostat
(ST3)
60ºC
82ºC
55ºC
– 60°C
Dryer temperature setting
The air
temperature on the ’
Classeq
’ dryer range is adjustable, but have been pre-set to:
Dryer air temperature
(ST4)
60ºC
The manual reset safety thermal trips on the machine are set to the following values and cannot be
adjusted:
Wash tank
– 85°C
Rinse boiler
– 95°C
Air blower
– 85°C
Table end limit switch
It is very important that the table end limit switch be installed at the end of the exit table and the arm
adjusted so that it is activated by the basket before it reaches the end of the table. The cable should
be routed through the small cable gland at the rear of the machine and plugged into the harness at the
connector near the small terminal block. The switch should be wired on the normally closed circuit.