ENGINEERS MANUAL
CST MACHINES AND DRYER UNIT
Drawn up: 05/10/2018
Document number : 30008893
Page 29 of 48
Revision: C
Machine breakers and timer wiring
Type
Breaker
size
Breaker
number
Wire colour / Connection configuration
6A
Circuit
breaker 5
Incoming wire from Filter 4A (P1)
Out going wire to On/Off switch
6A
Breaker 4
(3 phase
breaker)
Incoming wire from Terminal block (TB1)
Out going wire to Drive motor relay (RL6)
Incoming wire from Terminal block (TB1)
Out going wire to Drive motor relay (RL6)
Incoming wire from Terminal block (TB1)
Out going wire to Drive motor relay (RL6)
25A
Breaker 1
Incoming wire from terminal block (TB1)
Out going wire to heating contactor (CT1)
Incoming wire from Terminal block (TB1)
Out going wire to heating contactor (CT1)
Incoming wire from Terminal block (TB1)
Out going wire to heating contactor (CT1)
Breaker 2
Incoming wire from Terminal block (TB1)
Out going wire to heating contactor (CT2)
Incoming wire from Terminal block (TB1)
Out going wire to heating contactor (CT2)
Incoming wire from Terminal block (TB1)
Out going wire to heating contactor (CT2)
Breaker 3
Incoming wire from Terminal block (TB1)
Out going wire to heating contactor (CT3)
Incoming wire from Terminal block (TB1)
Out going wire to heating contactor (CT3)
Incoming wire from Terminal block (TB1)
Out going wire to heating contactor (CT3)