T H E C O N T I N U O U S P O W E R C O M P A N Y
Page 21
•
Unpack and ensure that all UPS System components are on-hand and operative:
o
UPS System Module
o
Power Interface Module (PIM) w/mounting bracket
o
Battery Module (8 batteries w/cabling)
•
Collect appropriate mounting hardware for the particular installation.
o
For 170/332 cabinets only, one or two battery trays (per shipping documents, depends
on version purchased)
•
Assemble your tools and inventory your equipment. Table 9 is a checklist of items that have
proved useful during previous installations.
•
Contact the responsible agencies to schedule a brief power down (10 to 15 minutes) at the
intersection(s) affected.
•
Allot 2 hours of time for the installation.
Table 9: RECOMMENDED INSTALLATION EQUIPMENT
Armored sheathing (cable protector)
Connectors (butt type and
insulated)
Cordless drill w/ bits and a spare
battery pack
Crimpers (for insulated and non-
insulated connectors)
Dikes
DVM w/ probes
Electrical Tape
Flat Head screwdriver
Hardware in spill-proof carrying case
Hold-downs (adhesive back)
Nut Driver Set
#2 Phillips head screwdriver
Phillips head drill bit
Propane torch (miniature) or
cigarette lighter
Shrink tubing
Socket Set
Socket Wrench
Tape measure
Wire cutters
Wire strippers