-13-
4. Within 5 seconds, press the transmitter button corresponding to the desired
operating mode that Parameter.
The siren will chirp a number of times equal to the transmitter button pressed.
5. When finished, turn the ignition OFF to save changes.
13.3 Default Reset for User Programming
1. Turn the ignition ON.
2. Within 5 seconds, press the Valet/Override button 2 times and hold for 2
seconds.
The siren will chirp, indicating that Programming has been entered.
3. Press transmitter button 3.
The siren will chirp 6 times indicating the reset signal has been received, and
User Parameters have been reset to factory default.
14. Installer Programmable Parameters
Installer Programming Table
1.
Door Unlock Pulse
Single
Double
2.
Door Lock/Unlock Pulse Width
1 Second
3 Seconds
3.
Passive Locking
Off
On
4.
Door Entry Delay w/ Passive Arming
Off
On
5.
Ignore Dome Light Delay
Off
On
6.
Auxiliary 1 Output
Momentary
Timed
Latched
7.
Auxiliary 2 Output
Momentary
Timed
Latched
8.
Auxiliary 2 Activate on Arm
Off
On
9.
Trunk Disarm Feature
Off
On
10. Lock on Remote Start
Off
On
11.
Lock on Remote Shutdown
Off
On
12. Engine Start Sense
Tach Sense
Tachless Operation
13. Program RPM
Learn RPM
Gas
Diesel
14.
2-way Transmitter Module
Learn Module ID
Learn Transmitter ID
15. Ignition 2 Relay Programming
Ignition 2
Accessory 2
Starter 2
16. Horn Output Programming
Horn
Ignition 3
Step 14 is reserved for use with optional Ungo-Net 2-way LCD transmitter module (included with MS2107).
Feature
Button 1 (default) Button 2
Button 3
MS2107 install.qxd 8/25/2003 12:50 PM Page 13
Содержание UNGO MS2105
Страница 18: ... 18 18 Dome Light Supervision Relay Diagrams Negative Door Pinswitch Positive Door Pinswitch ...
Страница 19: ... 19 19 Trunk Hatch Release Diagrams Negative Trunk Release Wire Positive Trunk Release Wire ...
Страница 21: ...Positive Door Lock System 21 22 Door Lock Diagrams Negative Door Lock System ...
Страница 22: ... 22 Reverse Polarity Door Lock System ...
Страница 23: ... 23 Actuator Diagram ...
Страница 24: ... 24 Vacuum Pump System ...
Страница 25: ... 25 Negative Door Lock System with Driver s Door Priority 23 Driver s Door Priority Wiring Diagrams ...
Страница 26: ... 26 Positive Door Lock System with Driver s Door Priority ...
Страница 27: ... 27 Reverse Polarity Door Lock System with Driver s Door Priority ...