-15-
13.
Program RPM:
This dual function programming step sets the engine type
(default is gas) and learns the idle tach setting.
Button 1: "Learns" the tach reference of the vehicle.
Button 2: Selects gasoline engine type.
Button 3: Selects diesel engine type.
Tach Learning notes:
To learn the tach setting of the vehicle, first set the
engine type. If the vehicle is gasoline powered, then no adjustment is needed.
Next, start the engine and enter the programming mode within five seconds.
Select step 13 and press transmitter button 1 to learn. The LED will flash once
to confirm tach learning, or five times if unable to learn the tach signal.
14.
2-way Transmitter Module:
(Requires Ungo-Net 2-way Transmitter Module)
Button 1: Learns the Ungo-Net 2-way module ID
Button 2: Learns the 2-way transmitter ID. Once the remote programming routine
has been entered, press button 1 on each 2-way transmitter (maximum 2).
15.
Ignition 2 Relay Programming:
Allows Ignition 2 output to be programmed for
use as a second ignition or second starter output instead.
16.
Horn Output Programming:
Allows the horn output to be programmed for use
as an output to trigger an ignition 3 relay.
14.2 Entering Installer Programming
1. Turn the ignition ON.
2. Within 5 seconds, press the Valet/Override button 5 times.
The siren will chirp, indicating that Installer Programming has been entered.
3. Press the Valet/Override button the number of times equal to the Parameter to
be changed.
The siren will chirp each time the Valet/Override button is pressed.
4. Within 5 seconds, press the transmitter button corresponding to the desired
operating mode that Parameter.
The siren will chirp corresponding to the button depressed.
5. When finished, turn the ignition OFF to save changes.
14.3 Default Reset for Installer Programming
1. Turn the ignition ON.
2. Within 5 seconds, press the Valet/Override button 5 times.
The siren will chirp, indicating that Programming has been entered.
3. Press transmitter button 3.
The siren will chirp 6 times indicating the reset signal has been received, and
Installer Parameters have been reset to factory default.
MS2107 install.qxd 8/25/2003 12:50 PM Page 15
Содержание UNGO MS2105
Страница 18: ... 18 18 Dome Light Supervision Relay Diagrams Negative Door Pinswitch Positive Door Pinswitch ...
Страница 19: ... 19 19 Trunk Hatch Release Diagrams Negative Trunk Release Wire Positive Trunk Release Wire ...
Страница 21: ...Positive Door Lock System 21 22 Door Lock Diagrams Negative Door Lock System ...
Страница 22: ... 22 Reverse Polarity Door Lock System ...
Страница 23: ... 23 Actuator Diagram ...
Страница 24: ... 24 Vacuum Pump System ...
Страница 25: ... 25 Negative Door Lock System with Driver s Door Priority 23 Driver s Door Priority Wiring Diagrams ...
Страница 26: ... 26 Positive Door Lock System with Driver s Door Priority ...
Страница 27: ... 27 Reverse Polarity Door Lock System with Driver s Door Priority ...