-14-
14.1 Installer Parameter Descriptions
1.
Door Unlock Pulse:
Selects between single or double unlock pulse.
2.
Door Lock Pulse Width:
Selects between a 1-second or 3-second door lock
pulse.
3.
Passive Locking:
Selects whether or not the door locks will automatically lock
with Auto Rearming and Passive Arming.
4.
Door Entry Delay with Passive Arming:
Selects whether or not the door
trigger input will be delayed for 15 seconds, allowing access to the Override
switch. The door trigger is delayed only when the system arms passively.
5.
Ignore Dome Light Delay:
Selects whether or not the security system will
ignore the door trigger for 20 seconds upon arming. For vehicles with timed
dome light delays, the system will not detect a faulty door trigger upon arming.
6.
Auxiliary 1 Output:
Selects between momentary, timed, or latched output for
Auxiliary 1.
Momentary: Provides an output that will remain active as long as transmitter
button is depressed.
Timed: Provides an output that will remain active for 30 seconds.
Latched: Provides an output that will activate when the transmitter button is
pressed and remain active until the the transmitter button is pressed again.
The latched output can be programmed to reset when the security system is
Armed or the ignition is turned On. (Requires the Ungo-Net computer interface
for programming.)
7.
Auxiliary 2 Output:
Selects between momentary, timed, or latched output for
Auxiliary 2 (see step 8 for descriptions).
8.
Auxiliary 2 Activate on Arm:
The security system can be programmed to
activate Auxiliary 2 when Armed. This feature can be used to turn on a piezo
warning indicator, roll up windows, etc.
9.
Trunk Disarm Feature:
This feature will automatically disarm the security
system when Auxiliary 1 is activated.
10.
Lock on Remote Start:
Selects whether or not the doors will lock after remote
starting.
11.
Lock on Remote Shutdown:
Selects whether or not the doors will lock after
remote start shutdown.
12.
Engine Start Sense:
Selects between Tach sense mode and Tachless
operation. Tach sense mode should always be used in extreme temperature
climates and in cases where the Tachless operation provides unsatisfactory
operation.
MS2107 install.qxd 8/25/2003 12:50 PM Page 14
Содержание UNGO MS2105
Страница 18: ... 18 18 Dome Light Supervision Relay Diagrams Negative Door Pinswitch Positive Door Pinswitch ...
Страница 19: ... 19 19 Trunk Hatch Release Diagrams Negative Trunk Release Wire Positive Trunk Release Wire ...
Страница 21: ...Positive Door Lock System 21 22 Door Lock Diagrams Negative Door Lock System ...
Страница 22: ... 22 Reverse Polarity Door Lock System ...
Страница 23: ... 23 Actuator Diagram ...
Страница 24: ... 24 Vacuum Pump System ...
Страница 25: ... 25 Negative Door Lock System with Driver s Door Priority 23 Driver s Door Priority Wiring Diagrams ...
Страница 26: ... 26 Positive Door Lock System with Driver s Door Priority ...
Страница 27: ... 27 Reverse Polarity Door Lock System with Driver s Door Priority ...