SM-P00077-A/3
2. INSTALLATION
45
2020-04-15
◼
Examples of terminal layouts for wiring method T10
Maximum number of stations on the manifold varies depending on the model. Check individual
specifications.
In the table below, each valve number (Valve no.) consists of a number (the station number) and an
alphabet (a for the a-side solenoid and b for the b-side solenoid). For example, “1a” refers to 1st station
a-side solenoid.
Terminal no.
COM
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
COM
<Standard wiring>
• Single solenoid valve
(Maximum of 16 stations)
Terminal no.
16
15
14
13
12
11
10
9
Valve no.
16a
15a
14a
13a
12a
11a
10a
9a
Terminal no.
8
7
6
5
4
3
2
1
Valve no.
8a
7a
6a
5a
4a
3a
2a
1a
• Double solenoid valve
(Maximum of 8 stations)
Terminal no.
16
15
14
13
12
11
10
9
Valve no.
8b
8a
7b
7a
6b
6a
5b
5a
Terminal no.
8
7
6
5
4
3
2
1
Valve no.
4b
4a
3b
3a
2b
2a
1b
1a
• Mixed (both single and double solenoid valves are mounted)
(Maximum of 16 solenoids)
Terminal no.
16
15
14
13
12
11
10
9
Valve no.
12a
11b
11a
10a
9a
8a
7b
7a
Terminal no.
8
7
6
5
4
3
2
1
Valve no.
6a
5a
4b
4a
3b
3a
2a
1a
<Double wiring>
• Single solenoid valve
(Maximum of 8 stations)
Terminal no.
16
15
14
13
12
11
10
9
Valve no.
Empty
8a
Empty
7a
Empty
6a
Empty
5a
Terminal no.
8
7
6
5
4
3
2
1
Valve no.
Empty
4a
Empty
3a
Empty
2a
Empty
1a
• Double solenoid valve
(Maximum of 8 stations)
Terminal no.
16
15
14
13
12
11
10
9
Valve no.
8b
8a
7b
7a
6b
6a
5b
5a
Terminal no.
8
7
6
5
4
3
2
1
Valve no.
4b
4a
3b
3a
2b
2a
1b
1a
• Mixed (both single and double solenoid valves are mounted)
(Maximum of 16 solenoids)
Terminal no.
16
15
14
13
12
11
10
9
Valve no.
8b
8a
7b
7a
Empty
6a
Empty
5a
Terminal no.
8
7
6
5
4
3
2
1
Valve no.
4b
4a
Empty
3a
2b
2a
1b
1a