SM-P00077-A/3
3. USAGE
68
2020-04-15
Operating
tab
3.2.2
Residual pressure exahust mechanism (option symbol: X, X1)
◼
How to open and close the cover
Do not apply excessive force to the cover when opening and closing the cover.
Excessive external force may cause damage (below 5 N).
◼
How to operate the manual override for residual pressure exhaust
<Non-locking type (option symbol: X)>
Push the operating tab in the direction of the arrow.
Residual pressure can be exhaused while the
operating tab is pushed.
Release the tab to finish residual pressure exhaust.
The tab returns to the original position when
released.
<Locking type (option symbol: X1)>
Push the operating tab in the direction of the arrow.
The tab is locked in place and residual pressure is
exhausted.
Return the tab to the original position to disable
residual pressure exhaust.
Cover