SM-P00077-A/3
2. INSTALLATION
59
2020-04-15
<For T53>
Part name
Model
Manufacturer
Socket
XG4M-2630
Omron Corporation
Strain relief
XG4T-2604
Discrete-wire press connector
XG5M-2632-N
Discrete-wire press connector
XG5M-2635-N
Discrete-wire crimp connector (socket)
XG5N-261-U
Discrete-wire crimp connector (contact)
XG5W-0231, 0232
◼
Cable
This system, in general, uses flat cables or thin multi-conductor cables. These cables have thin
conductors and must be checked that they have sufficient mechanical strength and electrical capacity for
the application.
• Make sure to make a rounded corner (R) when bending the flat cable.
• The cable has large electric resistance (approximately 0.22 Ω/m for AWG28). Use extreme care to
avoid a voltage drop along the cable. For example, when 16 solenoid valves are energized at 24 VDC,
a voltage drop of approximately 0.1 V/m will occur.