E.g. If the settings are as follows,
Factor = 1.02356
Accuracy = 0.00
LSD = 50
Now if 50 gm of weight is loaded on the pan the calculation for displayed weight will be as follows,
Weight * Factor
= 50 * 1.023456
= 51.1728
The displayed weight will be 51.150
The second digit after decimal point will change in multiples of 5 because,
Accuracy * LSD
= 50 * 0.001
= 0.05
You can use the <TOGGLE> key at any time to switch the display between custom unit display, weighing unit 1 and weighing unit
2. User can go to Standby mode by pressing on/off key and go to Simple Weighing with unit 1 by Cancel key and balance shows
Current weights.
60
Printouts generated when Unit Toggling is done
between Application Unit (
Cst
), Unit1 and
Unit2.
Printouts generated when Unit Toggling is done
between Application Unit (
Cst
), Unit1 and
Unit2.
When GLP ON
When GLP OFF
-----------------------------------
28-Jul-10 03:19PM
Citizen
Model
CX 220
Ser.no.
9223102
Ver.no.
r0.1.5.3
ID
1234567
-----------------------------------
LID:
1111111
Factor
3.023456
Accuracy
0.1
Lsd
2
+
151.2 cst
+
50.0000 g
+
250.000 ct
Factor
1.023456
Accuracy
0.001
Lsd
50
+
61.400 cst
+
51.200 cst
-----------------------------------
28-Jul-10
03:23PM
Name:
................
-----------------------------------
Factor
3.023456
Accuracy
0.1
Lsd
2
+
151.2 cst
+
50.0000 g
+
250.000 ct
Factor
1.023456
Accuracy
0.001
Lsd
50
+
61.400 cst
+
51.200 cst
If the balance is connected eternally to PC or Printer through RS 232 C then, whenever user enter into the Custom Unit Menu & make
changes in the Factor, Accuracy and LSD setting, automatically printout is generated on the Peripheral attached.
In the printout, the new Factor, Accuracy and LSD values are printed. After this user can Press Print Key to Print the reading on the display.
Also user can Toggle to other unit through Toggle key & Press Print Key to get the print out of those corresponding units.
Note :
1) User cannot enter into the external calibration or menu when GLP is ON
2) To print footer user will have to Press <CANCEL> key.
& footer has not been printed.
59