5-2
Cisco SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-07
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration
How to Set Up the Local Console
Figure 5-1
Connecting the Local Console to the SCE 2000 CON Port
Make sure that the terminal configuration is as follows:
•
9600 baud
•
8 data bits
•
No Parity
•
1 stop bits
•
No flow control
The above SCE 2000 port parameters are fixed and are not configurable.
Step 1
Plug the RS-232 serial cable provided with the SCE 2000 into the CON port on the front panel of the
SCE 2000.
Make sure that you push on the RJ-45 connector (attached to the RS-232 serial cable) until you hear a
“click”, which indicates that the connector is fully inserted and secured in the receptacle. Gently pull on
the plug to confirm whether the plug is locked into the socket.
Step 2
Connect the other end of the serial cable (with an attached DB-9 connector) to the VT100 compatible
local (serial) terminal.
Step 3
Make sure the local terminal is configured as a VT-100 terminal, according to the fixed SCE 2000 CON
port parameters.
Step 4
Press
Enter
several times until the Cisco logo appears on the local terminal and the setup configuration
dialog is entered.
--- System Configuration Dialog ---
At any point you may enter a question mark ‘?’ followed by ‘Enter’ for help.
Use ctrl-C to abort configuration dialog at any prompt.
Use ctrl-Z to jump to the end of the configuration dialog at any prompt.
Default settings are in square brackets ‘[]’.
Would you like to continue with the System Configuration Dialog? [yes/no]:
y
Step 5
Type
y and
press Enter.
The system configuration dialog begins.
LINK RX
Cisco SCE 2000
Series
4xGBE
TX
RX
MM
TX
LINK RX TX
RX
MM
TX
LINK RX TX
RX
MM
TX
LINK RX TX
RX
MM
TX
GBE-1
SUB
LINE
NET
PWR B STATU
S
PWR A
BYPASS
10/100/
1000
LINK/
ACTIVE
10/100/
1000
LINK/
ACTIVE
GBE-2
SUB LINE/CASCADE
NET
AUX
CONSOLE
MNG 2
MNG 1
92790
3
2
1