3-34
Cisco RF Gateway 10 Hardware Installation Guide
OL-16264-04
Chapter 3 Cisco RFGW-10 UEQAM Installation
Connecting the Lineage Power Shelf to the Cisco RFGW-10
Disconnecting Cables from the Power Shelf
Caution
Ensure that the power is turned off on the power shelf by disconnecting the power supply at the facility
before proceeding to disconnect the other cables.
Steps
To disconnect cables from the Lineage power shelf and the Cisco RFGW-10:
Step 1
Power off the power shelf by disconnecting the power supply at the facility. Wait a few minutes before
disconnecting the power cables so that they discharge.
Step 2
Disconnect the AC cables from the standard wall socket. Disconnect the AC power cables from each of
the AC-input power supply sources on the power shelf.
Step 3
Disconnect the DC power cables on each side of the DC power sources, on the power shelf.
Step 4
Disconnect the other ends of the DC power cable from the DC power terminal blocks of the
Cisco RFGW-10.