Chapter 2 Module Installation
14
78-4025693-01 Rev D
Installing the Module in the Chassis
To Install the Module
Important:
The following procedure assumes that the chassis is mounted in a rack.
This procedure applies to both front access and rear access chassis styles. The
modules are hot-swappable and have plug-and-play capability.
WARNING:
Avoid damage to your eyes! Do not look into any optical connector while the
system is active. Even if the unit is off, there may still be hazardous optical
levels present.
Important: When a module (power supply or application module) is inserted into
the chassis, alarm(s) may be generated momentarily while the module powers up.
This will be briefly indicated on the module LED and may also generate an alarm in
the Event Log. This is a normal occurrence and does not indicate a module problem.
Complete the following steps to install the module in the chassis.
1
Locate the fiber guides at the bottom of the chassis and the module guide slots
inside the chassis as shown in the following illustration.
2
Align the ridges on the top and bottom of the module with the module guide
slots located on the chassis.
3
Locate the two ejector levers on the left of the module. Swing the ejectors out so
they are perpendicular to the module front panel.
Содержание Prisma II
Страница 1: ...78 4025693 01 Rev D Prisma II Hybrid Amplifier Installation Guide ...
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 26: ......
Страница 54: ......
Страница 56: ...Chapter 3 Operation Using CLI 30 78 4025693 01 Rev D Prisma II Platform Configuration ...
Страница 150: ......
Страница 156: ......
Страница 164: ...Appendix A Prisma II Permitted CLI Commands 138 78 4025693 01 Rev D Reserved for future use ...
Страница 174: ......
Страница 180: ......