Hybrid Amplifier Parameters
78-4025693-01 Rev D
145
Note:
Monitored values may vary from module to module. The values shown above
are examples only.
Hybrid Amplifier Configurable Parameters
Parameter
Name (LCI)
ICIM
Abbreviation
Description
Values
Default
Enable Laser
Enable
Enables or disables amplifier
ON (1)
OFF (0)
OFF (0)
Optical Power
Attenuation
SetAtten
Attenuates optical output by value
selected
0 to 3 dB
in 0.5 dB steps
0 dB
Operational
Mode
Mode
Module redundancy control:
If set to Master, unit only
controlled by Enable controls
If set to Slave, unit only
controlled by external alarm
signal
Master (1)
Slave (0)
Master
(1)
Input Alarm
Laser Shutdown
LoInpEna
Disables low input power alarms
and shuts amplifier down when
optical input level falls below -10.0
dBm
ON (1)
OFF (0)
OFF (0)
Service Mode
Service
Sets optical output level to 15.0
dBm for servicing
ON (1)
OFF (0)
OFF (0)
Hybrid Amplifier Alarm Data Parameters
Parameter
Name (LCI)
ICIM
Abbrev.
Nominal
Value
Major
Low
Limit
Minor
Low
Limit
Minor
High
Limit
Major
High
Limit
Hys-
teresis
Operating
Range
Optical
Input
Power
1
InPwr
-
-16
dBm
-5.0
dBm
25
dBm
45
dBm
1.0
-
Optical
Output
Power
1
OutPwr
-
-1.0
dBm
-0.7
dBm
-0.7
dBm
1.0
dBm
0.1
-
Laser 1
Temperature
1
LasTemp1 25.0°C
-20.0°C -15.0°C 15.0°C
20.0°C
1.0
OK or
Alarm
Laser 2
Temperature
1
LasTemp2 25.0°C
-35.0°C -30.0°C 45.0°C
50.0°C
1.0
OK or
Alarm
Содержание Prisma II
Страница 1: ...78 4025693 01 Rev D Prisma II Hybrid Amplifier Installation Guide ...
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 26: ......
Страница 54: ......
Страница 56: ...Chapter 3 Operation Using CLI 30 78 4025693 01 Rev D Prisma II Platform Configuration ...
Страница 150: ......
Страница 156: ......
Страница 164: ...Appendix A Prisma II Permitted CLI Commands 138 78 4025693 01 Rev D Reserved for future use ...
Страница 174: ......
Страница 180: ......