Appendix B
Module Parameter Descriptions
144
78-4025693-01 Rev D
Hybrid Amplifier Parameters
Hybrid Amplifier Operating Status Parameters
Parameter
Name (LCI)
ICIM
Abbreviation
Function
Typical
Value
Optical Input
Power
InPwr
Displays optical input power
5.0 dBm
Optical Output
Power
OutPwr
Displays optical output power
19.5 dBm
Laser 1
Temperature
LasTemp1
Laser temperature for pump 1
25°C
Laser 2
Temperature
LasTemp2
Laser temperature for pump 2
25°C
Laser 1 Bias
Current
LasBias1
Laser bias current for pump 1
0.625 A
Laser 2 Bias
Current
LasBias2
Laser bias current for pump 2
3.25 A
Laser 1 Limit
LasLim1
Laser bias current limit for pump 1
0.825 A
Laser 2 Limit
LasLim2
Laser bias current limit for pump 2
6.25 A
Laser TEC
Current
TecCur
Laser TecCooler current for pump 1
0.25 A
Module
Temperature
ModTemp
Displays module temperature
26.5°C
Laser On Time LaserOn
Displays laser ON time
1.0 Hrs
Enable Laser
Enable
Enables or disables the amplifier
On
Optical Power
Attenuation
SetAtten
Attenuates optical output by value
selected
0 dB
Operational
Mode
Mode
Module redundancy control:
If set to Master, unit only controlled
by Enable controls
If set to Slave, unit only controlled
by external alarm signal
Master
Input Alarm
Laser Shutdown
LoInpEna
Disables low input power alarms and
shuts down amplifier when optical input
level falls below -10.0 dBm
Off
Service Mode
Service
Sets output level to 15 dBm for servicing Off
Содержание Prisma II
Страница 1: ...78 4025693 01 Rev D Prisma II Hybrid Amplifier Installation Guide ...
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 26: ......
Страница 54: ......
Страница 56: ...Chapter 3 Operation Using CLI 30 78 4025693 01 Rev D Prisma II Platform Configuration ...
Страница 150: ......
Страница 156: ......
Страница 164: ...Appendix A Prisma II Permitted CLI Commands 138 78 4025693 01 Rev D Reserved for future use ...
Страница 174: ......
Страница 180: ......