Chapter 6 Maintenance and Troubleshooting
128
78-4025693-01 Rev D
Troubleshooting Alarm Conditions
Amplifier Alarm Conditions
If the red ALARM indicator is illuminated or is blinking, check the ICIM2 display to
determine the cause of the alarm.
Alarm
Parameter
Possible Causes
Possible Solutions
LasBias
Laser current
Internal problem
Contact Customer Service
for assistance.
InPwr
Optical input
Dirty or loose connector
Low input
Check input source.
OutPwr
Optical output
Low input
Internal problem
Check input.
Contact Customer Service
for assistance.
Module disabled
Enable module.
LasTemp
Laser temperature Internal problem
Fan Tray failure
Ambient temperature
Chassis air filter requires
changing
Contact Customer Service
for assistance.
IntPs
Input power
supply
Internal problem
Contact Customer Service
for assistance.
Содержание Prisma II
Страница 1: ...78 4025693 01 Rev D Prisma II Hybrid Amplifier Installation Guide ...
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 26: ......
Страница 54: ......
Страница 56: ...Chapter 3 Operation Using CLI 30 78 4025693 01 Rev D Prisma II Platform Configuration ...
Страница 150: ......
Страница 156: ......
Страница 164: ...Appendix A Prisma II Permitted CLI Commands 138 78 4025693 01 Rev D Reserved for future use ...
Страница 174: ......
Страница 180: ......