Basic Administration of the SPA9000
Configuring Basic Settings
SPA9000 Voice System Administration Guide
35
2
STEP 5
Click Submit All Changes.
STEP 6
Enter the same multicast address in the phone configurations:
a. Click the
PBX Status
link to view a list of all phones.
b. Find the phone that you want to configure, and then click the hyperlink in the
IP
Address
column. The
Telephone Configuration
page appears in a separate
browser window.
c. Click the
SIP
tab.
d. Scroll down to the
Linksys Key System Parameters
section.
e. Enter the IP address in the
Multicast Address
field.
f.
Click
Submit All Changes
.
g. Click the
Back
button on the Internet Explorer toolbar to return to the list of
phones.
h. Repeat these steps for each phone.
Setting the Group Page Address
In the group paging application, the originator sends RTP packets to an IP
multicast address at which all the other client stations are listening. This address is
chosen by the SPA9000 and is configured on the
Voice > SIP
page,
PBX
Parameters
section,
Group Page Address
field.
The originator starts the group page by choosing
PageGroup
from the Corporate
Directory on the phone, or by using a speed dial or personal directory entry. All
client stations are alerted at once. If the client station is on a call when a group
page starts, the call is automatically placed on hold. The speaker on each paged
station is turned on automatically unless the handset or headset is being used.
Group page is one-way only. The paged client stations can only listen to the call
from the originator.
STEP 1
Connect to the SPA9000 administration web server, and choose Admin access
with Advanced settings. (See
“Connecting to the SPA9000 Administration Web
Server,” on page 27
).
STEP 2
Click
Voice tab > SIP
.
STEP 3
Scroll down to the
PBX Parameters
section.
Downloaded from
www.Manualslib.com