Displaying hardware health status
Cisco TelePresence ISDN Gateways v2.0 Online help (Printable format)
91 of 116
Displaying hardware health status
The Health Status displays information about the hardware components of the ISDN gateway. To
access this information, go to
Status > Health.
Note:
The
Worst status seen
conditions are those since the last time the unit was restarted.
To reset these values, click
Clear
. Refer to the table below for assistance in interpreting the
information displayed.
Field
Field description
Usage tips
Fans
Voltages
RTC battery
Displays two possible states:
OK
Out of spec
States indicate both
Current status
and
Worst status seen
conditions.
OK
– component is functioning
properly
Out of spec
– Check with your
support provider; component
might require service
If the
Worst status seen
column displays
"Out of spec", but
Current status
is
"OK", monitor the status regularly to verify
that it was only a temporary condition.
Temperature
Displays three possible states:
OK
Out of spec
Critical
States indicate both
Current status
and
Worst status seen
conditions.
OK
– temperature of the ISDN
gateway is within the appropriate
range
Out of spec
– Check the ambient
temperature (should be less than
34 degrees Celsius) and verify
that the air vents are not blocked
Critical
– temperature of ISDN
gateway is too high. An error also
appears in the event log
indicating that the system will
shutdown in 60 seconds if the
condition persists
If the
Worst status seen
column displays
"Out of spec", but
Current status
is
"OK", monitor the status regularly to verify
that it was only a temporary condition.