39-7
Cisco IE 3000 Switch Software Configuration Guide
OL-13018-03
Chapter 39 Troubleshooting
Recovering from Lost Cluster Member Connectivity
Step 10
When prompted, assign a name to the cluster, and press
Return
.
The cluster name can be 1 to 31 alphanumeric characters, dashes, or underscores.
Step 11
When the initial configuration displays, verify that the addresses are correct.
Step 12
If the displayed information is correct, enter
Y
, and press
Return
.
If this information is not correct, enter
N
, press
Return
,
and begin again at Step 9.
Step 13
Start your browser, and enter the IP address of the new command switch.
Step 14
From the Cluster menu, select
Add to Cluster
to display a list of candidate switches to add to the cluster.
Recovering from Lost Cluster Member Connectivity
Some configurations can prevent the command switch from maintaining contact with member switches.
If you are unable to maintain management contact with a member, and the member switch is forwarding
packets normally, check for these conflicts:
•
A member switch (Catalyst 3750, Catalyst 3560, Catalyst 3550, Catalyst 3500 XL, Catalyst 2970,
Catalyst 2960, Catalyst 2950, Catalyst 2900 XL, Catalyst 2820, and Catalyst 1900 switch) cannot
connect to the command switch through a port that is defined as a network port.
•
Catalyst 3500 XL, Catalyst 2900 XL, Catalyst 2820, and Catalyst 1900 member switches must
connect to the command switch through a port that belongs to the same management VLAN.
•
A member switch (Catalyst 3750, Catalyst 3560, Catalyst 3550, Catalyst 2970, Catalyst 2960,
Catalyst 2950, Catalyst 3500 XL, Catalyst 2900 XL, Catalyst 2820, and Catalyst 1900 switch)
connected to the command switch through a secured port can lose connectivity if the port is disabled
because of a security violation.
Preventing Autonegotiation Mismatches
The IEEE 802.3ab autonegotiation protocol manages the switch settings for speed (10 Mb/s, 100 Mb/s,
and 1000 Mb/s, excluding SFP module ports) and duplex (half or full). There are situations when this
protocol can incorrectly align these settings, reducing performance. A mismatch occurs under these
circumstances:
•
A manually set speed or duplex parameter is different from the manually set speed or duplex
parameter on the connected port.
•
A port is set to autonegotiate, and the connected port is set to full duplex with no autonegotiation.
To maximize switch performance and ensure a link, follow one of these guidelines when changing the
settings for duplex and speed:
•
Let both ports autonegotiate both speed and duplex.
•
Manually set the speed and duplex parameters for the ports on both ends of the connection.
Note
If a remote device does not autonegotiate, configure the duplex settings on the two ports to match. The
speed parameter can adjust itself even if the connected port does not autonegotiate.
Содержание IE 3000
Страница 36: ...xxxiv Cisco IE 3000 Switch Software Configuration Guide OL 13018 03 Preface ...
Страница 784: ...39 20 Cisco IE 3000 Switch Software Configuration Guide OL 13018 03 Chapter 39 Troubleshooting Troubleshooting Tables ...
Страница 874: ...Index IN 42 Cisco IE 3000 Switch Software Configuration Guide OL 13018 03 ...