22-4
Cisco IE 3000 Switch Software Configuration Guide
OL-13018-03
Chapter 22 Configuring Flex Links and the MAC Address-Table Move Update Feature
Understanding Flex Links and the MAC Address-Table Move Update
Leaking IGMP Reports
To achieve multicast traffic convergence with minimal loss, a redundant data path must be set up before
the Flex Link active link goes down. This can be achieved by leaking only IGMP report packets on the
Flex Link backup link. These leaked IGMP report messages are processed by upstream distribution
routers, so multicast data traffic gets forwarded to the backup interface. Because all incoming traffic on
the backup interface is dropped at the ingress of the access switch, no duplicate multicast traffic is
received by the host. When the Flex Link active link fails, the access switch starts accepting traffic from
the backup link immediately. The only disadvantage of this scheme is that it consumes bandwidth on the
link between the distribution switches and on the backup link between the distribution and access
switches. This feature is disabled by default and can be configured by using the
switchport backup
interface
interface-id
multicast fast-convergence
command.
When this feature has been enabled at changeover, the switch does not generate the proxy reports on the
backup port, which became the forwarding port.
Configuration Examples
These are configuration examples for learning the other Flex Link port as the mrouter port when Flex
Link is configured on GigabitEthernet1/1 and GigabitEthernet1/2, with output for the
show
interfaces
switchport backup
command:
Switch#
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#
interface GigabitEthernet1/1
Switch(config-if)#
switchport trunk encapsulation dot1q
Switch(config-if)#
switchport mode trunk
Switch(config-if)#
switchport backup interface Gi1/2
Switch(config-if)#
exit
Switch(config)#
interface GigabitEthernet1/2
Switch(config-if)#
switchport trunk encapsulation dot1q
Switch(config-if)#
switchport mode trunk
Switch(config-if)#
end
Switch#
show interfaces switchport backup detail
Switch Backup Interface Pairs:
Active Interface Backup Interface State
GigabitEthernet1/1 GigabitEthernet1/2 Active Up/Backup Standby
Preemption Mode : off
Multicast Fast Convergence : Off
Bandwidth : 100000 Kbit (Gi1/1), 100000 Kbit (Gi1/2)
Mac Address Move Update Vlan : auto
This output shows a querier for VLANs 1 and 401, with their queries reaching the switch through
GigabitEthernet1/1:
Switch#
show ip igmp snooping querier
Vlan
IP Address
IGMP Version
Port
-------------------------------------------------------------
1 1.1.1.1
v2
Gi1/1
401 41.41.41.1 v2
Gi1/1
Here is output for the
show ip igmp snooping mrouter
command for VLANs 1 and 401:
Switch#
show ip igmp snooping mrouter
Vlan ports
---- -----
1 Gi1/1(dynamic),
Gi1/2(dynamic)
401 Gi1/1(dynamic),
Gi1/2(dynamic)
Содержание IE 3000
Страница 36: ...xxxiv Cisco IE 3000 Switch Software Configuration Guide OL 13018 03 Preface ...
Страница 784: ...39 20 Cisco IE 3000 Switch Software Configuration Guide OL 13018 03 Chapter 39 Troubleshooting Troubleshooting Tables ...
Страница 874: ...Index IN 42 Cisco IE 3000 Switch Software Configuration Guide OL 13018 03 ...