5-6
Cisco H.323 Signaling Interface User Guide
OL-4806-01 Rev. A14
Chapter 5 Troubleshooting Cisco HSI Alarms
Troubleshooting
Troubleshooting
This section provides troubleshooting procedures for the alarms listed in
Table 5-4
.
H323_STACK_FAILURE
Description
Irrecoverable failure in the RADVision stack. This alarm is reported to the management interface and
can be obtained with SNMP.
Severity Level and Trap Type
The severity level is critical. The trap type is 4.
Cause
The H.323 RADVision stack has failed to correctly initialize on an application startup. An automatic
application restart is initiated, and the application reverts to the base configuration data
.
Troubleshooting
To clear the H.323 stack failure alarm, complete the following steps:
Step 1
Allow the application to restart and revert back to the base configuration data that is known to be reliable.
Step 2
Review the H323_SYS parameters in a provisioning session, ensuring that the values are correct and
within the memory limits of the machine.
Step 3
Use the
prov-cpy
MML command to recommit the new H323_SYS parameters.
Step 4
Use the
restart-softw
MML command to initiate a software restart.
Step 5
Use the
rtrv-alms
MML command to check the alarm list to see if the H.323 stack correctly initializes.
CONFIGURATION_FAILURE
Description
The configuration has failed. This alarm is reported to the management interface and can be obtained
with SNMP.
Severity Level and Trap Type
The severity level is major. The trap type is 4.
Содержание HSI 4.1
Страница 12: ...Contents xii Cisco H 323 Signaling Interface User Guide OL 4806 01 Rev A14 ...
Страница 180: ...C 20 Cisco H 323 Signaling Interface User Guide OL 4806 01 Rev A14 Appendix C Example of an HSI Configuration File ...
Страница 184: ...D 4 Cisco H 323 Signaling Interface User Guide OL 4806 01 Rev A14 Appendix D E ISUP Name to Cause Value Lookup ...
Страница 188: ...E 4 Cisco H 323 Signaling Interface User Guide OL 4806 01 Rev A14 Appendix E E ISUP Cause Value to Name Lookup ...