![Cisco FM3500 Endo Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/cisco/fm3500-endo/fm3500-endo_installation-and-configuration-manual_67773033.webp)
Hardware installation
© 2021 Cisco and/or its affiliates. All rights reserved.
Page 33 of 177
1. Power ON the unit.
2. Wait approximately 40 seconds for the unit to boot up.
3. When the unit has completed its boot sequence, press the
RESET
button for 7 seconds.
• The LEDs will blink.
• The unit will be restored to factory default settings
(including its default IP address of
192.168.0.10
and
subnet mask of
255.255.255.0
).
• The unit will reboot.
• The administrator user name and password will both be
reset to
admin
.
5.1.6. Suitability for outdoor installation
The Cisco FM3500 Endo was specifically designed for installation in harsh
outdoor environments. Under operating conditions, the unit is completely
sealed, and is capable of high-performance operation in outdoor
environments, and under severe conditions such as water spray, salt, and
extreme fluctuations in cold and heat.
The Cisco FM3500 Endo has successfully passed stringent environmental
certification tests, including European Committee for Standardization
(electronic equipment used on rolling stock for railway applications)
(fire protection on railway vehicles) tests.
Examples of specific certification tests included:
• Verification of resistance to salt water intrusion and corrosion. This
consisted of subjecting the unit to running, high-pressure salt water
for 24 hours, followed by a 24-hour drying time. The unit was then
carefully examined to verify that no corrosion or water ingress were
found.
• Verification of resistance to fluctuating temperatures. This consisted
of placing the unit in a climatic chamber and subjecting it to operating
ranges between -40°C and 80°C, for four hours.