Device configuration using the configurator interface
© 2021 Cisco and/or its affiliates. All rights reserved.
Page 105 of 177
3. Enable downstream (infrastructure to vehicle) Multicast traffic by
adding multicast route
224.5.5.6 / 5.255.255.255
to the global
gateway unit,
and
to the Mesh End unit in each subnet cluster.
7.7.6. SNMP configuration
The SNMP window can be used to configure an SNMP v2c or SNMP v3
service to run on the Cisco FM3500 Endo.
Walk-throughs (no agent-to-manager notifications) and traps (agent-to-
manager notifications enabled) are both supported. If SNMP traps are
enabled, you can specify the server address to which monitoring
information must be sent.
To change the SNMP settings, do the following steps:
•
Click the
-snmp
mode link under
ADVANCED SETTINGS
in the
left-hand settings menu.
• The default
SNMP
dialog will be shown (
IMPORTANT
If TITAN is enabled at core network level and dual-
redundant global gateway units are installed, do not
enter the global gateway's actual Mesh ID number as
the Destination Address. Instead, use Destination
Address
5.0.0.0
NOTE
5.255.255.255
is the wildcard address for all Mesh ID
destinations within the network.
IMPORTANT
The same SNMP configuration must be set for all Fluidmesh
units in the wireless network.
For detailed information on Fluidmesh unit SNMP configuration,
refer to the
Fluidmesh SNMP FM-MIB OID Table
and MIB
configuration files. These can be downloaded from the
Fluidmesh Partner Portal (
Documentation
section >
User
Manuals
>
Advanced Manuals
.)