Hardware installation
© 2021 Cisco and/or its affiliates. All rights reserved.
Page 30 of 177
The Cisco FM3500 Endo can be provided with power using the following
methods:
• A compatible 48 Vdc passive PoE injector conforming to
When providing the power source for the Cisco FM3500 Endo, remember
the following important points:
• Install the power source as close to the unit as possible to minimize
voltage drop. The maximum suggested distance is 165ft (50m).
• Ensure proper grounding (earthing) and reliable connectivity by
using shielded CAT5/6 cables and connectors.
Connecting power to the Cisco FM3500 Endo
Connecting power through a LAN Ethernet port
The Cisco FM3500 Endo radio transceiver unit has two Ethernet ports
(
IMPORTANT
The radio transceiver package does
not
include a DC IN power
source (devices capable of accepting DC IN power only), a PoE
injector, or a powered Ethernet switch. A suitable power source
must be ordered separately.
For technical data on which power sources are compatible with
the Cisco FM3500 Endo, refer to
CAUTION
Do not connect any PoE injector conforming to
to the unit.
Such injectors have a higher voltage variance than the
design specification of the unit allows for, and may result
in unreliable performance.
NOTE
For detailed comparative information on which Fluidmesh
hardware devices are capable of accepting power through
IEEE 802.3at or IEEE 802.3af power sources, or through a DC
IN power source, refer to
“Electrical power requirements” (page