327
Warning
Message
Type
Message
Cause/Remedy
Description
ID
CI Status
Set
Different CA
Systems in
Top/Bottom
Slots
Cause: Different CA
systems are used in the
slots.
Remedy: Replace the CA
cards to use the same
CA system.
Different CA Systems
in Top/Bottom slots.
42500
CI Status
Clear
OK
–
–
42500
Video Format
Mismatch
Set
Video format
mismatch
–
Video Format
Mismatch.
43000
Video Format
Mismatch
Clear
Video format
match
–
–
43000
Temperature
Warning
Set
Temperature
over Warning
threshold
Cause: Room
temperature too high, or
air flow is blocked.
Remedy: Check
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.
Temperature is above
normal operating
range.
44000
Temperature
Warning
Clear
Temperature
normal
–
Temperature is within
the normal operating
range.
44000
FPGA
Temperature
Warning
Set
Temperature
over Warning
threshold
Cause: Room
temperature is too high,
or air flow is blocked.
Remedy: Check the
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.
FPGA temperature is
above normal
operating range.
45000
FPGA
Temperature
Warning
Clear
Temperature
normal
–
FPGA temperature is
within the normal
operating range.
45000
VBI Data
Set
2nd VBI PID
attempt to write
same line
Cause: Uplink
configuration issue.
Remedy: Contact uplink
to verify expected VBI
settings.
Conflicting VBI data
on second VBI PID.
49000
Содержание D9824
Страница 22: ......
Страница 26: ...Chapter 1 Introduction 4 On Screen Display support on baseband output NIT Retune Recovery ...
Страница 40: ......
Страница 164: ......
Страница 306: ......
Страница 368: ......
Страница 370: ......
Страница 388: ......
Страница 410: ...Appendix C Compliance 388 Declarationof Conformity ...
Страница 415: ......