Chapter 5 Installing and Upgrading Internal Modules and FRUs
Replacing Power Supplies and Redundant Power Supplies
Step 7
Install the RPS blank panel.
Cisco 2911, 2921, and 2951 Power and RPS Error Messages
There are many RPS error messages unique to the Cisco 2911, 2921, and 2951 routers. The messages
appear on the router console terminal.
Table 5-4
lists the messages and their meanings.
Table 5-4
Cisco 2911, 2921, and 2951 Power and RPS Error Messages
Message
Condition
An unsupported RPS is connected or cable is not
inserted properly
During reload, IOS cannot read the RPS2300 PID,
or the RPS2300 PID does not match. The
RPS2300 PID is read over the I2C link between
the Router and the RPS2300. The error could also
indicate there is a cable connectivity problem.
Power supplies inserted in RPS are incompatible
RPS 2300 FRUs are different. FRUs can be either
1150W or 750W. The RPS does not support
differing FRUs. See
Table 5-2
.
RPS has a critical fault
During reload, the RPS2300 has an over-current,
over-temperature, or under-voltage condition.
RPS is not ready for configuration
RPS2300 is busy handling control or
configuration commands from the connected
LUs
1
, and the router is trying to send command to
the RPS2300.
RPS is not available for backup
RPS2300 is backing up other LUs and it cannot
backup the current router.
One critical RPS fault has occurred or RPS power
supply is not good
During runtime, the RPS2300 encountered an
over-current, over-temperature, or under-voltage
condition, or the power supplies is faulty.
RPS is disconnected or powered off
RPS2300 is disconnected or powered off.
An unsupported RPS is connected.
During reload or runtime, an unsupported
RPS2300 is connected to the router.
RPS OIR insertion is not supported. Reload the
router for power redundancy.
During runtime, the supported RPS2300 is
connected to the router.
Chassis power is not good in PSU 1
During runtime, the power input source was
removed from the internal power supply.
Input source is removed from PSU 1
During runtime, the power input source was
removed from the internal power supply.
PSU's PoE power is not good in slot 1
During runtime, the PoE power from the internal
power supply failed.
PSU is removed in slot 1
Internal power supply is removed.