background image

6-6

Catalyst 3650 Switch Hardware Installation Guide

OL-29734-01

Appendix 6      Technical Specifications

Power Supply Module Specifications

Voltage range international

PWR-C1-440WDC: –36 VDC (minimum), –48 VDC 
(nominal), –72 VDC (maximum)
PWR-C2-640WDC: –36 VDC (minimum) 
–60 VDC (nominal), –72 VDC (maximum)

Total input BTU

1

PWR-C1-440WDC 1841 BTUs per hour, 540 W
PWR-C2-640WDC 2444 BTUs per hour, 719 W

Total output BTU

1

PWR-C1-440WDC: 1502 BTUs per hour, 440 W
PWR-C2-640WDC: 2188 BTUs per hour, 640 W

Wire gauge for ground connection

PWR-C1-440WDC: 12 AWG or 8 AWG
PWR-C2-640WDC: 12 AWG or 8 AWG

Branch circuit protection

PWR-C1-440WDC: 20 A
PWR-C2-640WDC: 25 A

1.

The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The 
BTU ratings are based on –48 VDC (nominal).

Table 6-4

Power Specifications for DC-Power 24-and 48-Port Switches (continued)

Содержание Catalyst 3650

Страница 1: ...m Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco website at www cisco com go offices Catalyst 3650 Switch Hardware Installation Guide April 2016 Text Part Number OL 29734 01 ...

Страница 2: ... be limited by FCC regulations and you may be required to correct any interference to radio or television communications at your own expense You can determine whether your equipment is causing interference by turning it off If the interference stops it was probably caused by the Cisco equipment or one of its peripheral devices If the equipment causes interference to radio or television reception t...

Страница 3: ...isco UPOE Ports 1 11 Management Ports 1 11 USB Mini Type B Port 1 11 USB Type A Port 1 12 Uplink Ports 1 12 SFP SFP and QSFP Modules 1 13 LEDs 1 13 SYST LED 1 16 Port LEDs and Modes 1 16 USB Console LED 1 18 ACTV LED 1 18 STACK LED 1 19 RPS LED 1 19 PoE LED 1 20 Uplink Ports LEDs 1 20 Rear Panel 1 22 RJ 45 Console Port LED 1 23 StackWise Ports 1 23 Power Supply Modules 1 23 Power Supply for Cataly...

Страница 4: ...ata Stack 2 5 Switch Stacking Guidelines 2 5 Data Stack Cabling Configurations 2 5 Data Stack Bandwidth and Partitioning Examples 2 6 Power On Sequence for Switch Data Stacks 2 7 Changes to Switch Stack Membership 2 8 Installing the Switch 2 9 Rack Mounting 2 9 Attaching the Rack Mount Brackets 2 10 Mounting the Switch in a Rack 2 13 Table or Shelf Mounting 2 14 After Installing the Switch 2 14 Co...

Страница 5: ...lling the Fan 4 1 Overview 4 1 Fan Module Installation 4 2 Installation Guidelines 4 2 Installing a Fan Module 4 3 Finding the Fan Module Serial Number 4 4 C H A P T E R 5 Troubleshooting 5 1 Diagnosing Problems 5 1 Switch POST Results 5 1 Switch LEDs 5 1 Switch Connections 5 2 Bad or Damaged Cable 5 2 Ethernet and Fiber Cables 5 2 Link Status 5 2 10 100 1000 Port Connections 5 2 PoE and PoE Port ...

Страница 6: ...ackWise Adapters 7 6 Locating the StackWise Adapter Serial Number 7 7 StackWise Adapter Blanks 7 7 SFP and SFP Module Cable Specifications 7 8 Four Twisted Pair Cable Pinouts 7 8 Two Twisted Pair Cable Pinouts 7 9 Identifying a Crossover Cable 7 9 Console Port Adapter Pinouts 7 9 A P P E N D I X 8 Configuring the Switch with the CLI Based Setup Program 8 1 Accessing the CLI 8 1 Accessing the CLI T...

Страница 7: ...Contents vii Catalyst 3750 X and 3560 X Switch Hardware Installation Guide OL 19593 03 IP Settings 8 5 Configuring the Setup Program 8 5 ...

Страница 8: ...Contents viii Catalyst 3750 X and 3560 X Switch Hardware Installation Guide OL 19593 03 ...

Страница 9: ... system messages that you might receive or how to configure your switch See the switch software configuration guide the switch command reference and the switch system message guide on http www cisco com go cat3650_docs Document Conventions This document uses the following conventions Note Means reader take note Notes contain helpful suggestions or references to materials not contained in this manu...

Страница 10: ...bmitting a Service Request For information on obtaining documentation submitting a service request and gathering additional information see the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simp...

Страница 11: ... switch refers to a standalone switch and to a switch stack Switch Models page 1 1 Front Panel page 1 7 Rear Panel page 1 22 Management Options page 1 29 Switch Models Table 1 1 Catalyst 3650 Switch Models Switch Model Cisco IOS Image Description WS C3650 24TS L LAN Base Stackable 24 10 100 1000 Ethernet downlink ports 4 1 Gigabit SFP small form factor pluggable uplink ports 250 W power supply WS ...

Страница 12: ...upply WS C3650 48TD L LAN Base Stackable 48 10 100 1000 Ethernet downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink ports 250 W power supply WS C3650 24PD L LAN Base Stackable 24 10 100 1000 PoE downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink ports 640 W power supply WS C3650 48PD L LAN Base Stackable 48 10 100 1000 PoE downlink ports 2 1 Gigabit SFP uplink por...

Страница 13: ...ckable 24 10 100 1000 PoE downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink ports Fixed 640 W power supply WS C3650 48FQM L LAN Base Stackable 48 10 100 1000 Full PoE downlink ports 4 10 Gigabit SFP uplink ports Fixed 975 W power supply WS C3650 24TS S IP Base Stackable 24 10 100 1000 Ethernet downlink ports 4 1 Gigabit SFP uplink ports 775 W power supply WS C3650 48TS S IP Base ...

Страница 14: ...supply WS C3650 48TD S IP Base Stackable 48 10 100 1000 Ethernet downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink ports 250 W power supply WS C3650 24PD S IP Base Stackable 24 10 100 1000 PoE downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink ports 640 W power supply WS C3650 48PD S IP Base Stackable 48 10 100 1000 PoE downlink ports 2 1 Gigabit SFP uplink ports...

Страница 15: ...24 10 100 1000 PoE downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink ports Fixed 640 W power supply WS C3650 48FQM S IP Base Stackable 48 10 100 1000 Full PoE downlink ports 4 10 Gigabit SFP uplink ports Fixed 975 W power supply WS C3650 24TS E IP Services Stackable 24 10 100 1000 Ethernet downlink ports 4 1 Gigabit SFP uplink ports 250 W power supply WS C3650 48TS E IP Services ...

Страница 16: ...pply WS C3650 48TD E IP Services Stackable 48 10 100 1000 Ethernet downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink ports 250 W power supply WS C3650 24PD E IP Services Stackable 24 10 100 1000 PoE downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink ports 640 W power supply WS C3650 48PD E IP Services Stackable 48 10 100 1000 PoE downlink ports 2 1 Gigabit SFP up...

Страница 17: ...k ports 1025 W power supply WS C3650 48PQ E IP Services Stackable 48 10 100 1000 PoE downlink ports 4 10 Gigabit SFP uplink ports 640 W power supply WS C3650 48TQ E IP Services Stackable 48 10 100 1000 Ethernet downlink ports 4 10 Gigabit SFP uplink ports 250 W power supply WS C3650 24PDM E IP Services Stackable 24 10 100 1000 PoE downlink ports 2 1 Gigabit SFP uplink ports 2 10 Gigabit SFP uplink...

Страница 18: ...t any particular color scheme They are provided as a reference for various features and markings described within this guide Figure 1 1 Catalyst 3650 48PD L Switch Front Panel Figure 1 2 Catalyst 3650 24PS L Switch Front Panel 6 3 4 1 5 2 347809 01X 13X 12X 24X 25X 36X 37X 48X ACTV Catalyst 3650 48PoE 2X10G TE3 G1 G2 G3 G4 TE4 1 Mode button 4 USB Type A storage port 2 Status LEDs 5 10 100 1000 PoE...

Страница 19: ... 1 3 Catalyst 3650 24PDM Switches Front Panel 1 Mode button 4 USB Type A storage port 2 Status LEDs 5 10 100 1000 PoE Ethernet ports 3 USB mini Type B console port 6 Uplink ports 1 Mode button 4 USB Type A storage port 2 Status LEDs 5 10 100 1000 PoE Ethernet ports 3 USB mini Type B console port 6 Uplink ports ...

Страница 20: ...G 10G Ethernet ports use RJ45 connectors with Ethernet pinouts These ports do not support 10Mbps speed The 100M and 1G traffic requires Category 5 5e 6 unshielded twisted pair UTP cable at maximum cable length of 100 meters The 2 5G traffic requires Category 5e 6 6a UTP cable at maximum cable length of 100 meters The 5G traffic requires Category 5e UTP cable at maximum cable length of 70 meters an...

Страница 21: ... Switch on Cisco com Note The output of the PoE circuit has been evaluated as a Limited Power Source LPS per IEC 60950 1 Management Ports Ethernet management port see the Ethernet Management Port section on page 1 28 RJ 45 console port EIA TIA 232 see the RJ 45 Console Port section on page 1 28 USB mini Type B console port 5 pin connector You can connect the switch to a host such as a Windows work...

Страница 22: ...nactivity timeout which reactivates the RJ 45 console if the USB console has been activated and no input activity has occurred on the USB console for a specified time period After the USB console deactivates due to inactivity you cannot use the CLI to reactivate it Disconnect and reconnect the USB cable to reactivate the USB console For information on using the CLI to configure the USB console int...

Страница 23: ...Transceiver Modules Compatibility Matrix documentation at http www cisco com en US products hw modules ps5455 products_device_support_tables_list html The 40 Gigabit QSFP transceiver module is a hot swappable parallel fiber optical module with four independent optical transmit and receive channels These channels can terminate in another 40 Gigabit QSFP transceiver or the channels can be broken out...

Страница 24: ...29734 01 Chapter 1 Product Overview Front Panel Figure 1 6 Switch Front Panel LEDs 1 STAT status 5 PoE1 1 Only switches with PoE ports 2 DUPLX duplex 6 CONSOLE USB mini Type B console port 3 SPEED 7 SYST system 4 STACK 8 ACTV active 347616 1 2 3 4 5 7 8 01X 6 ...

Страница 25: ...Panel LEDs 1 STAT status 6 CONSOLE USB mini Type B console port 2 DUPLX duplex 7 SYST system 3 SPEED 8 ACTV active 4 STACK 9 RPS 5 PoE1 1 Only switches with PoE ports Note The illustrations of the Catalyst 3650 switch are not intended to depict any particular color scheme They are provided as a reference for various features and markings described within this guide ...

Страница 26: ...ort modes When you press the Mode button on any switch in the switch stack all the stack switches change to show the same selected mode For example if you press the Mode button on the active switch to show the SPEED LED all the other switches in the stack also show the SPEED LED Table 1 2 SYST LED Color System Status Off System is not powered on Green System is operating normally Blinking green Sw...

Страница 27: ...ps SPEED 10 100 1000 2 5G 5G 10G ports Off Port is operating at 10 Mb s Green Port is operating at 100 Mb s Single green flash on for 100 ms off for 1900 ms Port is operating at 1000 Mb s Double green flash Port is operating at 2 5G 5G or 10G link speeds Use CLI to determine link speeds SFP QSFP ports Off Port is not operating Blinking green Port is operating at up to 10 Gb s DUPLX duplex Off Port...

Страница 28: ...ecause it has exceeded a limit set in the switch software Caution PoE faults occur when noncompliant cabling or powered devices are connected to a PoE port Use only standard compliant cabling to connect Cisco prestandard IP Phones and wireless access points or IEEE 802 3af compliant devices to PoE ports You must remove from the network any cable or device that causes a PoE fault Amber PoE for the ...

Страница 29: ...up and the representative STACK LEDs are amber when the ports are down RPS LED The RPS LED is only available on Catalyst 3650 24PDM and 3650 48FQM switch models Amber An error occurred when the switch was selecting the active switch or another type of stack error occurred Slow blinking green Switch is in stack standby mode Table 1 6 ACTV LED continued Color Description 1 Stack member 1 4 LED blink...

Страница 30: ... G3 G4 and two right side uplink ports LEDs also labeled TE3 and TE4 This labeling represents two ports left side supporting SFP modules and two ports right side supporting SFP and SFP modules Four uplink port LEDs labeled G1 G2 G3 G4 and TE1 TE2 TE3 TE4 This labeling represents four slots supporting SFP and SFP modules Ports labelled 1 to 8 This labelling represents eight ports supporting SFP and...

Страница 31: ...ble 1 9 Uplink Ports LEDs Color Uplink Ports Link Status Off Link is off Green Link is on no activity Blinking green Activity on a link no faults Blinking amber Link is off due to a fault or because it has exceeded a limit set in the switch software Caution Link faults occur when noncompliant cabling is connected to an SFP or SFP port Use only standard compliant cabling to connect to Cisco SFP and...

Страница 32: ...gure 1 10 Catalyst 3650 Switch Rear Panel Figure 1 11 Catalyst 3650 24PDM and 3650 48FQM Switches Rear Panel 1 Ground connector 5 StackWise port connector 2 CONSOLE RJ 45 console port 6 AC OK input status LED 3 MGMT RJ 45 10 100 1000 management port 7 PS OK output status LED 4 Fan module 8 Power supply modules AC power supply modules shown CONSOLE MGMT MGMT 347678 1 2 7 4 4 8 5 5 6 7 6 8 PWR C2 25...

Страница 33: ... equipment Note You cannot have a switch stack containing a mix of Catalyst 3650 and Catalyst 3850 switches Power Supply Modules Power Supply for Catalyst 3650 24TS PS TD PD and 3650 48TS PS FS TD PD FD FQ PQ TQ Switches page 1 24 Power Supply Module for Catalyst 3650 24PDM and 3650 48FQM Switches page 1 25 Power Supply Module LEDs page 1 26 The 24 and 48 port switches are powered through one or t...

Страница 34: ... switch models the following power supply modules are supported PWR C2 250WAC WS C3650 24TS L WS C3650 48TS L WS C3650 24PS L WS C3650 48PS L WS C3650 48FS L WS C3650 24US L WS C3650 48US L WS C3650 24TD L WS C3650 48TD L WS C3650 24PD L WS C3650 48PD L WS C3650 48FD L WS C3650 24UD L WS C3650 48UD L WS C3650 48FQ L WS C3650 48PQ L WS C3650 48TQ L WS C3650 24TS S WS C3650 48TS S WS C3650 24PS S WS...

Страница 35: ...le PoE Power 24 port data switch PWR C2 250WAC 48 port data switch 24 port PoE switch PWR C2 640WAC 390 W 48 port PoE switch 48 port full PoE switch PWR C2 1025WAC 775 W Table 1 12 Available PoE with DC Power Supply1 1 The 640 W DC PWR C2 640WDC power supply is the only DC module Models Number of Power Supplies Available PoE Power 24 port PoE switch 1 390 W 2 780 W 48 port PoE switch 1 390 W 2 780...

Страница 36: ...vices at a time It senses when the internal power supply of a connected device fails and provides power to the failed device preventing loss of network traffic For Table 1 14 Available PoE with Fixed Power Supply Models Power Supply Available PoE Power 24 port PoE switch 640 W 390 W 48 port PoE switch 975 W 775 W Table 1 15 Switch Power Supply Module LEDs AC Power Supply Module LEDs AC OK Descript...

Страница 37: ...pply module Read and monitor backup failure and exception history Fan Modules The switch has three internal hot swappable 12 V fan modules The air circulation system consists of the fan modules and the power supply modules The airflow patterns vary depending on the power supply configuration Figure 1 12 shows the airflow patterns for the 24 and 48 port switches The blue arrow shows cool air flow a...

Страница 38: ...to a host such as a Windows workstation or a terminal server through the 10 100 1000 Ethernet management port or one of the console ports see Figure 1 10 The 10 100 1000 Ethernet management port is a VPN routing forwarding VRF interface and uses a RJ 45 crossover or straight through cable Table 1 17 shows the Ethernet management port LED colors and their meanings RJ 45 Console Port The RJ 45 conso...

Страница 39: ...stant application see the Getting Started with Cisco Network Assistant guide on Cisco com Device Manager You can use Device Manager which is in the switch memory to manage individual and standalone switches This web interface offers quick configuration and monitoring You can access Device Manager from anywhere in your network through a web browser For more information see the getting started guide...

Страница 40: ...t Overview Management Options Network Configurations See the switch software configuration guide on Cisco com for network configuration concepts and examples of using the switch to create dedicated network segments and interconnecting the segments through Gigabit Ethernet connections ...

Страница 41: ...uide on Cisco com Preparing for Installation Safety Warnings page 2 1 Installation Guidelines page 2 3 Tools and Equipment page 2 4 Safety Warnings This section includes the basic installation caution and warning statements Translations of the warning statements appear in the Regulatory Compliance and Safety Information for the Catalyst 3650 Switch document available at Cisco com Read this section...

Страница 42: ...ecting the system to the power source Statement 1004 Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Warning The plug socket combination must be accessible at all times because it serves as the main disconnecting device Statement 1019 Warn...

Страница 43: ...bles that exit from either the left or right side of the switch should be routed and tied to the nearest rack metal Note The grounding architecture of this product is DC isolated DC I Installation Guidelines Before installing the switch verify that these guidelines are met For the clearance to the front and rear panels make sure that Front panel indicators can be easily read Clearance is at least ...

Страница 44: ...wever these fans and blowers can draw dust and other particles causing contaminant buildup inside the chassis which can result in system malfunction You must install this equipment in an environment as free from dust and foreign conductive material such as metal flakes from construction activities as is possible These standards provide guidelines for acceptable working environments and acceptable ...

Страница 45: ...parately and installed Before connecting the switches in a stack observe these stacking guidelines Size of the switch and any optional power supply module The 1025 W and 1100 W power supply modules is longer than the other modules Stacking switches with the same power supply modules together makes it easier to cable the switches Length of StackWise cable Depending on the configurations that you ha...

Страница 46: ...ect the switches This configuration provides redundant connections Figure 2 2 Data Stacking up to Four Switches in a Side by Side Mounting Data Stack Bandwidth and Partitioning Examples This section provides examples of data stack bandwidth and possible data stack partitioning Figure 2 3 shows a data stack of Catalyst 3650 switches that provides full bandwidth and redundant StackWise cable connect...

Страница 47: ...n the switches in a stack The sequence in which the switches are first powered on might affect the switch that becomes the active switch and the standby switch There are two ways to elect an active switch If you want a particular switch to become the active switch configure it with the highest priority Among switches with same priority the switch with the lowest MAC address becomes the active swit...

Страница 48: ... with an identical model the new switch functions with exactly the same configuration as the replaced switch assuming that the new switch referred to as the provisioned switch is using the same member number as the replaced switch The operation of the switch stack continues uninterrupted during membership changes unless you remove the active switch or you add powered on standalone switches or swit...

Страница 49: ...h Rack Mounting page 2 9 Table or Shelf Mounting page 2 14 After Installing the Switch page 2 14 The illustrations shown in this section show the Catalyst 3650 48 PoE switch as an example You can install other Catalyst 3650 switches following the same procedures Rack Mounting To install the switch in a 19 inch rack follow the instructions described in this section The 19 inch brackets are included...

Страница 50: ...illips flat head screws to attach the long side of the brackets to the switch for the front or rear mounting positions Figure 2 8 Use four screws to attach the brackets for the front mounting position 1 19 inch brackets RACK KIT T1 4 23 inch brackets RACK KIT T1 2 Extension rails and brackets for four point mounting includes 19 inch brackets 4PT KIT T1 5 24 inch brackets RACK KIT T1 3 ETSI bracket...

Страница 51: ... Switch Installation Installing the Switch Figure 2 8 Attaching Brackets for 19 inch Racks 1 Rear mounting position 2 Number 8 Phillips flat head screws 3 Front mounting position Catalyst 3650 48 PoE 4X 10G Catalyst 3650 48 PoE 4X 10G 2 2 2 2 347813 2 2 3 2 2 1 3 WR C2 640W AC ...

Страница 52: ...2 12 Catalyst 3650 Switch Hardware Installation Guide OL 29734 01 Chapter 2 Switch Installation Installing the Switch Figure 2 9 Attaching Brackets for Catalyst 3650 24PDM and 3650 48FQM Switches ...

Страница 53: ...he left or right bracket When you complete the switch installation see the After Installing the Switch section on page 2 14 for more information switch configuration Figure 2 10 Mounting the Switch in a Rack When you complete the switch installation see the After Installing the Switch section on page 2 14 for more information about switch configuration 1 Phillips machine screw black 3 Front mounti...

Страница 54: ... the switch installation see the After Installing the Switch section on page 2 14 for more information about the switch configuration After Installing the Switch After the switch is installed you might need to Configure the switch by running Express Setup to enter the initial switch configuration For instructions see the switch getting started guide that shipped with the switch and also on Cisco c...

Страница 55: ...o step 4 Step 2 Remove the StackWise adapter blanks from each destination StackWise port using the Torx T15 Allen key provided in the stacking kit or a Torx T15 screwdriver as shown in Figure 2 12 Store them for future use Step 3 Install a StackWise adapter in each destination StackWise port and secure in place using the supplied Torx T15 key or a Torx T15 screwdriver as shown in Figure 2 13 Note ...

Страница 56: ...tackWise Adapter Blank from a StackWise Port Figure 2 13 Installing the StackWise Adapter in a StackWise Port 1 Torx T15 screwdriver 4 StackWise adapter blank 2 Assembly screw 5 StackWise port 3 Cisco logo 6 CONSOLE MGMT 347822 1 4 2 3 5 1 Torx T15 screwdriver 4 StackWise adapter 2 Assembly screw 5 StackWise port 3 Cisco logo CONSOLE MGMT 347840 1 2 4 3 5 ...

Страница 57: ... If the StackWise cable is difficult to remove you can use a flat blade screwdriver to assist with removing the cable screws The screwdriver only works for cable removal and is designed to slip off if used for cable installation Installing and Removing SFP and SFP Modules See these sections for information on SFPs and SFP Installing SFP and SFP Modules page 2 17 Removing SFP or SFP Modules page 2 ...

Страница 58: ...nnecting cables to the switch and other devices Observe these precautions Step 1 Attach an ESD preventive wrist strap to your wrist and to an earth ground surface Step 2 Find the send TX and receive RX markings that identify the top of the SFP module On some SFP modules the send and receive TX and RX markings might be shown by arrows that show the direction of the connection Step 3 If the SFP modu...

Страница 59: ...ule has a bale clasp latch pull the bale out and down to eject the module If you cannot use your finger to open the latch use a small flat blade screwdriver or other long narrow instrument to open it Step 5 Grasp the SFP module and carefully remove it from the slot Step 6 Place the SFP module in an antistatic bag or other protective environment Connecting Devices to the Ethernet Ports 10 100 1000 ...

Страница 60: ...nd reference on Cisco com for more information about enabling or disabling autonegotiation and auto MDIX If auto MDIX is disabled use the guidelines in Table 2 1 to select the correct cable for connecting the switch 10 100 1000 Ethernet ports to other devices 100M 1G 2 5G 5G 10G Ethernet Port Connections The 100M 1G 2 5G 5G 10G Ethernet ports use RJ45 connectors with Ethernet pinouts These ports d...

Страница 61: ...ccess points that do not fully support IEEE 802 3af might not support PoE when connected to the switches by a crossover cable Caution PoE faults are caused when noncompliant cabling or powered devices are connected to a PoE port Use only standard compliant cabling to connect Cisco prestandard IP Phones wireless access points or IEEE 802 3af compliant devices to PoE ports A cable or device that cau...

Страница 62: ...area can be accessed only through the use of a special tool lock and key or other means of security Statement 1072 Where to Go Next If the default configuration is satisfactory the switch does not need further configuration You can use any of these management options to change the default configuration Start the Network Assistant application which is described in the Getting Started with Cisco Net...

Страница 63: ...ower Supply Module Overview The switch operates with either one or two active power supply modules You can use two AC modules two DC modules one AC and one DC module or one module and a blank cover Note In a NEBS installation you can use two DC modules or one DC module and a blank cover All switches ship with a blank cover in the second power supply slot if switches are configured with only one po...

Страница 64: ...upports input voltages between 36 and 72 VDC The output voltage range is 51 to 57 V Each AC power supply module has a power cord for connection to an AC power outlet The 640 W 715 W 1025 W and 1100 W and modules use a 16 AWG cord only North America All other modules use an 18 AWG cord All other modules use an 18 AWG cord The DC power supply module must be wired to a DC power source Note For inform...

Страница 65: ...ower Supply Module 1 1100 W AC power supply module 5 Release latch 2 AC OK LED 6 Power cord retainer 3 PS OK LED 7 Keying feature 4 AC power cord connector AC OK PWR C1 1100WAC PS OK 334375 1 7 6 2 3 4 5 1 715 W AC power supply module 5 Release latch 2 AC OK LED 6 Power cord retainer 3 PS OK LED 7 Keying feature 4 AC power cord connector AC OK PWR C1 715WAC PS OK 334376 1 6 2 3 4 5 7 ...

Страница 66: ...D 7 Release latch 3 PS OK LED 8 Extraction handle 4 Input power terminals positive polarity 9 Terminal block safety cover 5 Input power terminals negative polarity 10 Keying feature DC OK PWR C1 440WDC PS OK 334378 1 8 2 3 7 4 5 6 5 4 I N P U T 3 6 T O 7 2 V 1 2 A O U T P U T 4 4 W M A X 2 2 A 9 10 1 AC OK LED 4 AC power cord connector 2 PS OK LED 5 Release latch 3 AC power cord retainer 6 1025 W ...

Страница 67: ...igure 3 6 250 W AC Power Supply Module 1 AC OK LED 4 AC power cord connector 2 PS OK LED 5 Release latch 3 AC power cord retainer 6 640 W AC power supply module PS OK AC OK PWR C2 250WAC 347622 3 5 6 4 1 2 1 AC OK LED 4 AC power cord connector 2 PS OK LED 5 Release latch 3 AC power cord retainer 6 250 W AC power supply module PS OK AC OK PWR C2 250WAC 347622 3 5 6 4 1 2 ...

Страница 68: ...Supply Slot Blank Cover The power supply modules have two status LEDs 1 640 W DC power supply module 6 Grounding terminal 2 DC OK LED 7 Release latch 3 PS OK LED 8 Extraction handle 4 Input power terminals positive polarity 9 Terminal block safety cover 5 Input power terminals negative polarity DC OK PWR C2 640WDC PS OK D C I N P U T 3 6 V t o 7 2 V 2 1 1 0 5 A O U T P U T 6 4 0 W M A X 1 2 V 2 0 ...

Страница 69: ...tion hot swap the power supply ensuring that the remaining supply has sufficient PoE power for all powered ports For the switch commands that display available power budget see the software configuration guide Note For information on 250 W AC power supply support on the PoE capable switch models refer to the Release Notes for the Cisco Catalyst 3650 Switch on Cisco com Caution Do not operate the s...

Страница 70: ...wed to install replace or service this equipment Statement 1030 Installing or Replacing an AC Power Supply Step 1 Turn off the power at its source Step 2 Remove the power cord from the power cord retainer Step 3 Remove the power cord from the power connector Step 4 Press the release latch at the right side of the power supply module inward and slide the power supply out Figure 3 9 Caution Do not l...

Страница 71: ...er source Step 8 Confirm that the power supply AC OK and PS OK LEDs are green See for a description of the power supply module LEDs Installing a DC Power Supply Equipment That You Need page 3 10 Grounding the Switch page 3 10 Installing the DC Power Supply in the Switch page 3 13 Wiring the DC Input Power Source page 3 13 Warning An exposed wire lead from a DC input power source can conduct harmfu...

Страница 72: ...imping tool with optional controlled cycle mechanism model CT 720 CT 920 CT 920CH CT 930 or CT 940CH Wire stripping tools 12 gauge copper ground wire insulated or not for the single hole ground connection 8 gauge copper ground wire insulated or not for the dual hole ground connection Dual hole ground lug and two screws included in the DC Power Supply Accessory Kit and single hole ground lug and sc...

Страница 73: ...7 mm 0 02 inch 0 5 mm Figure 3 11 Stripping more than the recommended amount of wire can leave exposed wire from the connector Use 12 gauge copper ground wire for the single hole ground connection Use 8 gauge copper ground wire for the dual hole ground connection Figure 3 11 Stripping the Ground Wire Step 3 Slide the open end of the ground lug over the exposed area of the wire Step 4 Using a Pandu...

Страница 74: ... OL 29734 01 Chapter 3 Power Supply Installation Installing a DC Power Supply Figure 3 13 Attaching the Ground Lug and Wire Assembly 1 Single hole ground screw and lug ring 2 Dual hole ground adapter and dual hole lug 347788 1 2 CONSOLE MGMT CONSOLE MGMT ...

Страница 75: ... and gently push it into the slot Figure 3 14 When correctly installed the DC power supply excluding the extraction handle is flush with the switch rear panel Figure 3 14 Inserting the DC Power Supply in the Switch Step 6 Connect the input power as described in the Wiring the DC Input Power Source section Wiring the DC Input Power Source Step 1 Using a wire stripping tool strip each of the four wi...

Страница 76: ...f in Step 5 Replace the terminal block safety cover Step 6 Move the DC power source circuit breakers to the ON position Step 7 Confirm that the power supply DC OK and PS OK LEDs are green See Table 3 2 for a description of the module LEDs Finding the Power Supply Module Serial Number If you contact Cisco Technical Assistance regarding a power supply module you need to know the serial number See Fi...

Страница 77: ...de OL 29734 01 Chapter 3 Power Supply Installation Finding the Power Supply Module Serial Number Figure 3 17 1100 W AC Power Supply Serial Number Figure 3 18 1025 W AC Power Supply Serial Number SN XXXNNNNXXXX PWR C1 1100WAC 334333 347803 SN AAANNNNXXXX ...

Страница 78: ...witch Hardware Installation Guide OL 29734 01 Chapter 3 Power Supply Installation Finding the Power Supply Module Serial Number Figure 3 19 715 W and 350 W AC Power Supply Serial Number 334334 SN XXXNNNNXXXX PWR C1 715WAC ...

Страница 79: ...650 Switch Hardware Installation Guide OL 29734 01 Chapter 3 Power Supply Installation Finding the Power Supply Module Serial Number Figure 3 20 440 W DC Power Supply Serial Number 334335 SN XXXNNNNXXXX PWR C1 440W DC ...

Страница 80: ...50 Switch Hardware Installation Guide OL 29734 01 Chapter 3 Power Supply Installation Finding the Power Supply Module Serial Number Figure 3 21 640 W and 250 W AC Power Supply Module Serial Number 347805 SN AAANNNNXXXX ...

Страница 81: ...st 3650 Switch Hardware Installation Guide OL 29734 01 Chapter 3 Power Supply Installation Finding the Power Supply Module Serial Number Figure 3 22 640 W DC Power Supply Module Serial Number 347804 SN AAANNNNXXXX ...

Страница 82: ...3 20 Catalyst 3650 Switch Hardware Installation Guide OL 29734 01 Chapter 3 Power Supply Installation Finding the Power Supply Module Serial Number ...

Страница 83: ...t 3650 24PDM and 3650 48FQM switches These switches come with fixed fan modules and require no separate installation Overview The switch has three fan modules Fan modules are hot swappable A powered switch should always have more than one operational fan The switch can operate with two operational fans and one nonfunctional fan but the failed fan should be replaced as soon as possible to avoid a s...

Страница 84: ...y when StackWise adapters or StackWise adapter blanks are installed in each port Observe these guidelines when removing or installing a fan module Do not force the fan module into the slot This can damage the pins on the switch if they are not aligned with the module A fan module that is only partially connected can disrupt the system operation The switch supports hot swapping of the fan module Yo...

Страница 85: ...an module in the fan slot and firmly push it into the slot applying pressure to the end of the module not the extraction handles When correctly inserted the fan module is flush with the switch rear panel When the fan is operating a green LED is on in the top left corner of the fan See Figure 4 2 Warning Do not reach into a vacant slot when installing or removing a module Exposed circuitry is an en...

Страница 86: ...ding the Fan Module Serial Number Finding the Fan Module Serial Number If you contact Cisco Technical Assistance regarding a fan module you need to know the fan module serial number See Figure 4 3 for the serial number location Figure 4 3 Fan Module Serial Number SN XXXNNNNXXXX 334328 781 00761 01 ...

Страница 87: ...on guide the switch command reference guide on Cisco com or the documentation that came with your SNMP application for details Switch POST Results Approximately 30 seconds after the switch powers on it begins the power on self test POST which can take up to 5 minutes to complete During POST the SYSTEM LED blinks green When POST is complete the SYSTEM LED turns solid green the ACTV LED is green if ...

Страница 88: ...either Category 5 Category 5e or Category 6 UTP for 10 100 or 10 100 1000 Mbps connections Verify that you have the correct fiber optic cable for the distance 100 meters or less and port type Make sure that the connected device ports match and use the same type encoding optical frequency and fiber type For more information about cabling see the Determine if a copper crossover cable was used when a...

Страница 89: ... Caution Noncompliant cabling or powered devices can cause a PoE port fault Use only compliant cabling to connect Cisco prestandard IP phones wireless access points or IEEE 802 3af compliant devices Note The output of the PoE circuit has been evaluated as a limited power source LPS per IEC 60950 SFP Modules Use only Cisco SFP modules Inspect the uplink port and SFP module Exchange the suspect modu...

Страница 90: ...ction UDLD on the switch to help identify unidirectional link problems For information about enabling UDLD on the switch see the Understanding UDLD section in the software configuration guide on Cisco com Switch Performance Speed Duplex and Autonegotiation Port statistics that show a large amount of alignment errors frame check sequence FCS or late collisions errors might mean a speed or duplex mi...

Страница 91: ...clear the IP address that is configured on the switch Note Resetting the switch reboots the switch To reset the switch 1 Press and hold the Mode button The switch LEDs begin blinking after about 2 seconds If the LEDs above the mode button turn solid green you can release the Mode button and run Express Setup to configure the switch If the LEDs do not turn solid green continue with the next step 2 ...

Страница 92: ... to the stack If you had manually set the member numbers for the switch stack manually assign the member number of the failed switch to the replacement switch To manually assign the stack member number see the switch software configuration guide on Cisco com 4 Make the same Gigabit Ethernet connections on the replacement switch that were on the failed switch 5 Reinstall any modules and cable conne...

Страница 93: ...0ºC up to 10 000 feet 3000m 5ºC to 35ºC up to 13 000 feet 4000m 5ºC to 30ºC up to 16 400 feet 5000m Short term exceptional conditions1 2 5ºC to 50ºC up to 5000 feet 1500m 5ºC to 45ºC up to 10 000 feet 3000m 5ºC to 40ºC up to 13 000 feet 4000m 5ºC to 35ºC up to 16 400 feet 5000m 5ºC to 45ºC at sea level with single fan failure Operating temperature ranges and altitude for Catalyst WS C3650 24PDM WS...

Страница 94: ...st 3650 24 port non PoE switches 1 73 x 17 5 x 17 625 in 4 4 x 44 5 x 44 8 cm Catalyst 3650 24 port PoE switches 1 73 x 17 5 x 17 625 in 4 4 x 44 5 x 44 8 cm Catalyst 3650 48 port non PoE switches 1 73 x 17 5 x 17 625 in 4 4 x 44 5 x 44 8 cm Catalyst 3650 48 port PoE switches 1 73 x 17 5 x 17 625 in 4 4 x 44 5 x 44 8 cm Catalyst 3650 48 port Full PoE switches 1 73 x 17 5 x 19 125 in 4 4 x 44 5 x 4...

Страница 95: ...Minimum ambient temperature for cold start is 32 F 0 C 2 Occurring not more than in one year period 96 consecutive hours 360 hours in total or 15 occurrences 3 Minimum ambient temperature for cold start is 32 F 0 C 4 Occurring not more than in one year period 96 consecutive hours 360 hours in total or 15 occurrences Table 6 1 Environmental and Physical continued Specifications continued Environmen...

Страница 96: ...1100WAC 3 lb 1 4 kg PWR C1 440WDC 2 6 lb 1 2 kg PWR C2 1025WAC 3 55 lb 1 61 kg PWR C2 640WAC 3 1 lb 1 41 kg PWR C2 250WAC 2 55 lb 1 16 kg PWR C2 640WDC 2 75 lb 1 25 kg PWR C2 BLANK 0 2 lb 0 09 kg Physical Specifications Dimensions H x W x D PWR C1 715WAC 1 58 X 3 25 X 12 21 in 40 1 X 82 55 X 310 1 mm PWR C1 1100WAC 1 58 X 3 25 X 13 71 in 40 1 X 82 55 X 348 2 mm PWR C1 440WDC 1 58 X 3 25 X 12 21 in...

Страница 97: ...per hour 695 W PWR C2 250WAC 945 BTUs per hour 277 W Total output BTU1 PWR C1 1100WAC 3751 BTUs per hour 1100 W PWR C1 715WAC 2438 BTUs per hour 715 W PWR C2 1025WAC 3497 BTUs per hour 1025 W PWR C2 640WAC 2183 BTUs per hour 640 W PWR C2 250WAC 853 BTUs per hour 250 W 1 The total input and total output BTU ratings refer to input power to the power supply and output power to the switch The BTU rati...

Страница 98: ...0 W PWR C2 640WDC 2444 BTUs per hour 719 W Total output BTU1 PWR C1 440WDC 1502 BTUs per hour 440 W PWR C2 640WDC 2188 BTUs per hour 640 W Wire gauge for ground connection PWR C1 440WDC 12 AWG or 8 AWG PWR C2 640WDC 12 AWG or 8 AWG Branch circuit protection PWR C1 440WDC 20 A PWR C2 640WDC 25 A 1 The total input and total output BTU ratings refer to input power to the power supply and output power...

Страница 99: ... Environmental and Physical Specifications Environmental Ranges Operating temperature 23 to 176 F 5 to 80 C Storage temperature 40 to 185 F 40 to 85 C Relative humidity 5 to 96 non condensing Altitude Up to 16 400 ft 5 000 m Physical Specification Dimensions H x D x W 1 62 x 1 73 x 4 24 in 4 11 x 4 39 x 10 76 cm Weight 0 2 lb 0 07 kg Operating Specification Airflow 20 cfm ...

Страница 100: ...6 8 Catalyst 3650 Switch Hardware Installation Guide OL 29734 01 Appendix 6 Technical Specifications Fan Module Specifications ...

Страница 101: ... Connector Specifications 10 100 1000 Ports page 7 1 100M 1G 2 5G 5G 10G Ports page 7 2 10 Gigabit Ethernet CX1 SFP Copper Connectors page 7 2 SFP and SFP Modules page 7 3 10 100 1000 Ethernet Management Port page 7 4 Console Port page 7 4 10 100 1000 Ports The 10 100 1000 Ethernet ports on switches use RJ 45 connectors and Ethernet pinouts Figure 7 1 10 100 1000 Port Pinouts 60915 2 3 1 4 5 6 7 8...

Страница 102: ...0G Port Pinouts 10 Gigabit Ethernet CX1 SFP Copper Connectors The 10 Gigabit Ethernet electrical modules use CX1 copper connectors similar to the one shown in Figure 7 3 Note When ordering or using CX1 cables ensure that the version identifier is 2 or higher The 10 Gigabit Ethernet optical modules use the connectors shown in Figure 7 4 and Figure 7 5 Figure 7 3 10 Gigabit Ethernet CX1 Copper Conne...

Страница 103: ...e SFP module patch cable a 0 5 meter copper passive cable with SFP module connectors at each end Figure 7 7 This cable can be used only with 1 Gigabit Ethernet SFP ports to connect two Catalyst 3650 switches in a cascaded configuration Figure 7 4 Duplex LC Cable Connector Figure 7 5 Simplex LC Cable Connector Figure 7 6 Copper SFP Module RJ 45 Connector 58476 57834 60915 2 3 1 4 5 6 7 8 Pin Label ...

Страница 104: ... 7 8 10 100 1000 Port Pinouts Console Port The switch has two console ports a USB 5 pin mini Type B port on the front panel see Figure 7 9 and an RJ 45 console port on the rear panel Figure 7 9 USB Mini Type B Port The USB console port uses a USB Type A to 5 pin mini Type B cable shown in Figure 7 10 The USB Type A to USB mini Type B cable is not supplied You can order an accessory kit part number...

Страница 105: ...5 female DTE adapter if you want to connect the switch console port to a terminal You can order a kit part number ACS DSBUASYN containing that adapter For console port and adapter pinout information see Table 7 2 and Table 7 3 Cable and Adapter Specifications StackWise Cables page 7 5 StackWise Adapters page 7 6 StackWise Adapter Blanks page 7 7 SFP and SFP Module Cable Specifications page 7 8 Fou...

Страница 106: ...stacking port to enable stacking The StackWise cable connects to the StackWise adapter in the stacking port For switches ordered with stacking the StackWise adapters are preinstalled If the switches are not ordered with stacking the adapters must be ordered separately and installed You can order a StackWise adapter as part of a StackWise stacking upgrade kit part number C3650 STACK KIT that contai...

Страница 107: ...12 Location of the Serial Number on the StackWise Adapter StackWise Adapter Blanks A StackWise adapter blank is installed in the stacking port if stacking is not specified at the time of ordering the switch The StackWise adapter blank is screwed into the stacking port and must be removed and replaced by a StackWise adapter if the port is to be used for stacking Figure 7 13 shows a StackWise adapte...

Страница 108: ...ry 5 cable at lengths up to 328 feet 100 meters For cabling specifications refer to the Cisco Transceiver Modules data sheet at http www cisco com en US products hw modules ps5455 products_data_sheets_list html Four Twisted Pair Cable Pinouts Figure 7 14 Four Twisted Pair Straight Through Cable Schematic Figure 7 15 Four Twisted Pair Crossover Cable Schematic 1 TPO 2 TPO 3 TP1 6 TP1 1 TP1 Switch R...

Страница 109: ...ame color as the wire connected to the pin on the outside of the right plug See Figure 7 18 Figure 7 18 Identifying a Crossover Cable Console Port Adapter Pinouts The console port uses an 8 pin RJ 45 connector which is described in Table 7 2 and Table 7 3 If you did not order a console cable you need to provide an RJ 45 to DB 9 adapter cable to connect the switch console port to a PC console port ...

Страница 110: ... console port RJ 45 to DB 25 female DTE adapter and the console device Note The RJ 45 to DB 25 female DTE adapter is not supplied with the switch You can order a kit with the adapter part number ACS DSBUASYN from Cisco Table 7 2 Console Port Signaling Using a DB 9 Adapter Switch Console Port DTE RJ 45 to DB 9 Terminal Adapter Console Device Signal DB 9 Pin Signal RTS 8 CTS DTR 6 DSR TxD 2 RxD GND ...

Страница 111: ...Ethernet management port to the Ethernet port of your PC or workstation To put the switch into Express Setup mode follow the steps described in the Catalyst 3650 Getting Started Guide for powering on the switch and using Express Setup When the switch is in Express Setup mode open a Telnet session to the switch by entering the IP address 10 0 0 1 Enter the setup user EXEC command Enter the informat...

Страница 112: ... the terminal emulation program on the PC or the terminal The program frequently a PC application such as HyperTerminal or ProcommPlus makes communication between the switch and your PC or terminal possible Step 3 Configure the baud rate and character format of the PC or terminal to match the console port characteristics 9600 baud 8 data bits 1 stop bit No parity None flow control Step 4 Connect p...

Страница 113: ...s makes communication between the switch and your PC or terminal possible Step 4 Configure the baud rate and character format of the PC or terminal to match the console port default characteristics 9600 baud 8 data bits 1 stop bit No parity None flow control Step 5 Connect power to the switch Step 6 The PC or terminal displays the bootloader sequence Press Enter to display the setup prompt Follow ...

Страница 114: ...e Add or Remove Programs Utility Uninstalling the Cisco Microsoft Windows USB Driver Using the Setup exe Program Uninstalling the Cisco Microsoft Windows USB Driver Using the Add or Remove Programs Utility Uninstalling the Cisco Microsoft Windows XP USB Driver Uninstalling the Cisco Microsoft Windows Vista and 7 USB Driver Uninstalling the Cisco Microsoft Windows XP USB Driver Note Disconnect the ...

Страница 115: ... click Finish Entering the Initial Configuration Information To set up the switch you need to complete the setup program which runs automatically after the switch is powered on You must assign an IP address and other configuration information necessary for the switch to communicate with the local routers and the Internet This information is also needed to useDevice Manager or Cisco Network Assista...

Страница 116: ...rd and press Return Enter enable password enable_password Step 5 Enter a virtual terminal Telnet password and press Return The password can be from 1 to 25 alphanumeric characters is case sensitive allows spaces but ignores leading spaces Enter virtual terminal password terminal password Step 6 To configure the country code enter yes and press Return Do you want to configure country code no yes St...

Страница 117: ... 106 255 0 0 0 interface GigabitEthernet4 0 1 interface GigabitEthernet4 0 2 interface GigabitEthernet4 0 3 output abbreviated end Step 11 These choices appear 0 Go to the IOS command prompt without saving this config 1 Return back to the setup without saving this config 2 Save this configuration to nvram and exit If you want to save the configuration and use it the next time the switch reboots se...

Страница 118: ...8 8 Catalyst 3650 Switch Hardware Installation Guide OL 29734 01 Appendix 8 Configuring the Switch with the CLI Based Setup Program Entering the Initial Configuration Information ...

Отзывы: