2-14
Cisco ASR 14000 Series Router 8-Slot Line Card Chassis Installation Guide
OL-16973-01
Chapter 2 Installing and Removing Power Components
How to Install or Remove the Power Components
Prerequisites
Before performing this task, make sure that the PDU has been installed (see the
) and remove any cosmetic covers.
Required Tools and Equipment
You need the following tools and part to perform this task:
•
ESD-preventive wrist strap
•
Medium Phillips screwdriver
•
Power module
–
ASR14KAC rectifier Cisco product number ASR14K-8-AC-RECT=
–
DC PEM Cisco product number ASR14K-8-DC-PEM=
Steps
To install a power module, follow these steps:
Step 1
Attach the ESD-preventive wrist strap to your wrist and connect its leash to one of the ESD connection
sockets on the front (PLIM) side of the chassis or a bare metal surface on the chassis.
Step 2
Make sure that the power switch is in the off position.
Step 3
Grasp the handle on the top of the module firmly, and lift it partway up.
Step 4
Using two hands to support and guide the power module, slide it into the chassis power bay on the front
(PLIM) side of the chassis until the connector on the back of the module meets the connector on the
backplane of the PDU.
Caution
An AC rectifier weighs 36 lbs (13.44 kg); a DC PEM weighs 38 lbs (17.24 kg). You should
use both hands when handling a power module.
Step 5
Press the power module in firmly to seat it against the PDU.
Caution
To prevent damage to the PDU-to-module connections, do not use excessive force when
seating a power module to its PDU.
Step 6
Tighten the two captive screws on the face of the power module to seat it snugly against the PDU.
Step 7
Push the power tab at the bottom front of the module in to the on position.
1
Power switch
3
Handle
2
Module air filter
4
Captive screws