A-36
Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.0
OL-18504-01
Chapter A Troubleshooting
Troubleshooting the Appliance
sensor#
configure terminal
sensor(config)#
service
interface
sensor(config-int)#
physical-interfaces GigabitEthernet0/1
sensor(config-int-phy)#
admin-state enabled
sensor(config-int-phy)#
show settings
<protected entry>
name: GigabitEthernet0/1
-----------------------------------------------
media-type: tx <protected>
description: <defaulted>
admin-state: enabled default: disabled
duplex: auto <defaulted>
speed: auto <defaulted>
alt-tcp-reset-interface
-----------------------------------------------
none
-----------------------------------------------
-----------------------------------------------
-----------------------------------------------
-----------------------------------------------
sensor(config-int-phy)#
Step 4
Check to see that the interface is up and receiving packets.
sensor#
show interfaces
MAC statistics from interface GigabitEthernet0/1
Media Type = TX
Missed Packet Percentage = 0
Inline Mode = Unpaired
Pair Status = N/A
Link Status = Up
Link Speed = Auto_100
Link Duplex = Auto_Full
Total Packets Received = 3
Total Bytes Received = 900
Total Multicast Packets Received = 3
Total Broadcast Packets Received = 0
Total Jumbo Packets Received = 0
Total Undersize Packets Received = 0
Total Receive Errors = 0
Total Receive FIFO Overruns = 0
Total Packets Transmitted = 0
Total Bytes Transmitted = 0
Total Multicast Packets Transmitted = 0
Total Broadcast Packets Transmitted = 0
Total Jumbo Packets Transmitted = 0
Total Undersize Packets Transmitted = 0
Total Transmit Errors = 0
Total Transmit FIFO Overruns = 0 ...
For More Information
For the procedure for installing the sensor properly, refer to your sensor chapter in this document.