2-867
Catalyst 3750 Switch Command Reference
OL-8552-07
Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
system env temperature threshold yellow
the red threshold is 66 degrees C and you want to configure the yellow threshold as 51 degrees C, set the
difference between the thresholds as 15 by using the
system env temperature threshold yellow 15
command.
Note
The internal temperature sensor in the switch measures the internal system temperature and might vary
±
5 degrees C.
Examples
This example sets 15 as the difference between the yellow and red thresholds:
Switch(config)#
system env temperature threshold yellow 15
Switch(config)#
Related Commands
Command
Description
temperature status
Displays the temperature status and threshold levels.