2-212
Catalyst 3750 Switch Command Reference
OL-8552-07
Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
ip arp inspection log-buffer
ip arp inspection log-buffer
Use the
ip arp inspection
log-buffer
global configuration command to configure the dynamic Address
Resolution Protocol (ARP) inspection logging buffer. Use the
no
form of this command to return to the
default settings.
ip arp inspection log-buffer
{
entries
number
|
logs
number
interval
seconds
}
no ip arp inspection log-buffer
{
entries
|
logs
}
Syntax Description
Defaults
When dynamic ARP inspection is enabled, denied or dropped ARP packets are logged.
The number of log entries is 32.
The number of system messages is limited to 5 per second.
The logging-rate interval is 1 second.
Command Modes
Global configuration
Command History
Usage Guidelines
A value of 0 is not allowed for both the
logs
and the
interval
keywords.
The
logs
and
interval
settings interact. If the
logs
number
X is greater than
interval
seconds
Y, X
divided by Y (X/Y) system messages are sent every second. Otherwise, one system message is sent every
Y divided by X (Y/X) seconds. For example, if the
logs
number
is 20 and the
interval
seconds
is 4, the
switch generates system messages for five entries every second while there are entries in the log buffer.
A log buffer entry can represent more than one packet. For example, if an interface receives many
packets on the same VLAN with the same ARP parameters, the switch combines the packets as one entry
in the log buffer and generates a system message as a single entry.
If the log buffer overflows, it means that a log event does not fit into the log buffer, and the output
display for the
show ip arp inspection log
privileged EXEC command is affected. A -- in the output
display appears in place of all data except the packet count and the time. No other statistics are provided
for the entry. If you see this entry in the display, increase the number of entries in the log buffer, or
increase the logging rate.
entries
number
Number of entries to be logged in the buffer. The range is 0 to 1024.
logs
number
interval
seconds
Number of entries needed in the specified interval to generate system messages.
For
logs
number
, the range is 0 to 1024. A 0 value means that the entry is placed
in the log buffer, but a system message is not generated.
For
interval
seconds
, the range is 0 to 86400 seconds (1 day). A 0 value means
that a system message is immediately generated (and the log buffer is always
empty).
Release
Modification
12.2(20)SE
This command was introduced.
Содержание 3750 - Catalyst EMI Switch
Страница 494: ...2 464 Catalyst 3750 Switch Command Reference OL 8552 07 Chapter 2 Catalyst 3750 Switch Cisco IOS Commands reserved only ...
Страница 772: ...2 742 Catalyst 3750 Switch Command Reference OL 8552 07 Chapter 2 Catalyst 3750 Switch Cisco IOS Commands show vtp ...
Страница 1132: ...D 2 Catalyst 3750 Switch Command Reference OL 8552 07 Appendix D Acknowledgments for Open Source Software ...