DC Output Contactors:
There are 5 DC output contactors:
• Two for CHAdeMO cable.
• Two for CCS2 cable.
• One for CCS2 precharge circuit.
Output contactors allow Welding detection function. When one of the contactors is
welded, Mode 4 control board will receive this information and will identify which is the
faulty contactor. An alarm will be generated to avoid incoming charging sessions.