Service Manual
91
Raption
Maintenance
The maintenance plan is based in years from start-up, hours of charging or standby,
and cycles of charging. Depending of the group of components, is necessary to apply a
specific maintenance period. Check the periods in the next table:
Raption
WearCheck list, Key:
I
→
Inspection,
R
→
Replace,
- →
No maintenance needed
Years from start-up
6 months /
2K cycles
1 year /
4K cycles
2 years/
8K cycles
3 years /
12K cycles
4 years /
16K cycles
5 years /
20K cycles
Estimated time (hours)
for replacement
General maintenance
Preventive maintenance
I
I
I
I
I
I
1,5
Control devices
Screen ensemble Raption
-
I
I
I
I
R
0,3
Connectors and sockets
Type 2 Connector
-
I
I
R
I
I
0,75
CCS Connector
-
I
I
R
I
I
0,75
CHAdeMO Conector
-
I
I
R
I
I
0,75
Power
Power modules
-
I
I
I
I
R
0,25
Extra power supply
I
I
R
I
R
I
0,15
Contactors and relays
Switching contactors
-
-
I
-
I
R
0,5
Switching relays
-
-
I
-
I
R
0,15
Power contactors/relays
-
I
R
I
R
I
2
Ventilation and heating
Control part fans
-
I
I
R
I
I
1,5
Power part fans
-
I
I
I
I
R
1
Filters
-
R
R
R
R
R
1
Isolation top hat seal
-
R
R
R
R
R
0,5
Содержание Raption Series
Страница 1: ...Raption Series SERVICE MANUAL M186C01 03 21B...
Страница 10: ...Raption 10 Service Manual B Dimensions Units specified in millimeters...
Страница 12: ...Raption 12 Service Manual 1 A ELECTRONIC BOARDS ETC Raption 50...
Страница 23: ...Service Manual 23 Raption 6 BLOCK DIAGRAM...
Страница 25: ...Service Manual 25 Raption...
Страница 47: ...Service Manual 47 Raption...
Страница 63: ...Service Manual 63 Raption...
Страница 110: ...Raption 110 Service Manual...