Nov 8 09:39:18 raption user.info pss[306]: ------------------- VECTOR OF ERROR FLAGS OBJECTS ------------------- Error
Flags Object -> Module Type: 31,
Name: CCS2 Error flags: 0000 0000 0000 0000 0000 0000 0000 0020
Historical error flags: 0000 0000 0000 0000 0000 0000 0000 0120
Predecessor errors: 0 - 0
Status message flags: 0000 0000 0000 0000 0000 0001 0000 0001
Historical status message flags: 0000 0000 0000 0000 0000 0001 0000 0001
Predecessor status messages: 0 - 0 State machines: 701 700 2080 80 1 0 701 700 1080 80 1203
Nov 8 09:39:18 raption user.info pss[311]: ------------------- VECTOR OF ERROR FLAGS OBJECTS ------------------- Error
Flags Object -> Module Type: 10,
Name: Converter Error flags: 0000 0000 0000 0000 0000 0000 0000 0000
Historical error flags: 0000 0009 0000 0000 0000 0000 0000 4000
Predecessor errors: 0 - 0 Status message flags: 0000 0000 0000 0000 0000 0000 0000 0000
Historical status message flags: 0000 0000 0000 0000 0000 0000 0000 0000
Predecessor status messages: 0 - 0 State machines: 2 803 802 801 800 0 0 0 0 0 0
At first, it is shown the part of the error related with the Connector and then, the
Converter error. Same format as in the Display, which can be easily decoded.
Содержание Raption Series
Страница 1: ...Raption Series SERVICE MANUAL M186C01 03 21B...
Страница 10: ...Raption 10 Service Manual B Dimensions Units specified in millimeters...
Страница 12: ...Raption 12 Service Manual 1 A ELECTRONIC BOARDS ETC Raption 50...
Страница 23: ...Service Manual 23 Raption 6 BLOCK DIAGRAM...
Страница 25: ...Service Manual 25 Raption...
Страница 47: ...Service Manual 47 Raption...
Страница 63: ...Service Manual 63 Raption...
Страница 110: ...Raption 110 Service Manual...