Raption
34
Service Manual
Mode 3 Charge Controller (A6) is responsible for conducting the Mode 3 communications
and allows charging electrical vehicle as defined by IEC 61851 for AC side.
Communication to the device is only possible via RS485 communications through inputs
1 and 2. The device integrates an Ethernet port, which does not allow connectivity to
TCP/IP networks. It is used for internal use as digital inputs and outputs.
The default configuration modbus address is set at 96 and baud rate is set to 19200bps.
Item
Name
Function
1
PP- EV Connection
Proximity (PP)
2
CP-EV Connection
Control Pilot (CP)
3
A- RS-485 BUS
Terminal (+)
4
B- RS-485 BUS
Terminal (-)
5
A1- Power Supply
12 V
6
A2- Power Supply
0 V
7
RL- Contactor
Contactor coil
8
Ground
Ground
Mode 3 Device