- 13 -
Bottle Hookup and Ignition (LP Units only)
NOTE: Liquid withdrawal requires optional hose adapters and engine vaporizer.
1)
Place 100 lb. propane bottle(s) in rack and secure in place with chain binder(s). Model
225 melter uses (2) bottles, Model 105 holds (1).
2)
Connect hoses (A) to bottle(s).
NOTE: POL fittings are left hand thread. All connections must be air tight.
3)
Close hand torch supply valve (B). (optional)
4)
On models with two bottles, open the valve (C) from one bottle or the other.
5)
Open valve on LP bottle and set regulator (D) at 13 to 14 PSI.
WARNING: DO NOT exceed 14 PSI.
6)
Set the oil controller (E) to 550º F.
DO NOT
exceed 550º F. Set the material controller
(F) to the recommended material working temperature (typically listed on can or box).
(optional)
7)
Ignite the burner by turning the toggle switch (G) "on".
NOTE: If the burner does not ignite within 8-10 seconds, the unit will require reset-
ting. Turn switch "off", allow time for the unburned fuel to exit the chamber
and repeat procedure.
8)
If ignition does not occur, check the fuse and gas supply.
B
A
C
D
C
A
E
F
G
Содержание 105
Страница 43: ... 43 Hydraulic Schematic B2 A2 A1 B1 MD1 MD2 G2 R2 CS1 093 1500PSI R1 P T Model 105 1100 PSI Model 225 800 PSI ...
Страница 49: ... 49 Wiring Diagrams Complete Wiring Diagram No Heated Hose OilThermocouple Material Thermocouple ...
Страница 67: ... 67 6 11 12 1 7 10 5 3 4 2 13 9 Miscellaneous Parts ...
Страница 70: ... 70 Notes ...
Страница 72: ...2601 Niagara Lane Plymouth MN 55447 763 557 1982 800 328 3874 Fax 763 557 1971 ...