Material System Cleanout
AIR CLEANOUT METHOD (OPTIONAL)
1)
Place material pump in neutral.
2)
Remove sealing tip and return wand to access port..
3)
Open wand valve (F) and sealing hose valve (A).
4)
Close tank outlet valve (D).
5)
Increase (close) pressure valve (B) to maximum
.
6)
Connect air hose and open air cleanout valve.
7)
Allow air to blow freely through sealing hose. (Turn wand valve (F), open and closed
several times during this phase, to aid in cleaning valve. Leave valve open).
8)
Open tank outlet valve (D) momentarily, then close.
9)
Decrease (open) pressure valve (B) and leave open.
10)
Close sealing hose valve (A).
11)
Shut air hose off at compressor, close air cleanout valve and disconnect hose.
12)
Proceed with normal machine shut down.
FLUSHING NON-REHEATABLE MATERIALS
1)
Pump the material tank as low as possible.
2)
Add 5 to 10 gallons of recommended flushing solvent to tank.
3)
Place the wand into access port and open wand valve.
4)
Circulate the solvent approximately 5 to 10 minutes.
5)
Pump the solvent through the wand into a container and dispose of it according to EPA
guidelines.
6)
Add another 5 to 10 gallons of material and circulate for 5 minutes.
7)
Pump this 5 to 10 gallons into empty containers and reuse it for the first purge next time
the unit is used.
Содержание 105
Страница 43: ... 43 Hydraulic Schematic B2 A2 A1 B1 MD1 MD2 G2 R2 CS1 093 1500PSI R1 P T Model 105 1100 PSI Model 225 800 PSI ...
Страница 49: ... 49 Wiring Diagrams Complete Wiring Diagram No Heated Hose OilThermocouple Material Thermocouple ...
Страница 67: ... 67 6 11 12 1 7 10 5 3 4 2 13 9 Miscellaneous Parts ...
Страница 70: ... 70 Notes ...
Страница 72: ...2601 Niagara Lane Plymouth MN 55447 763 557 1982 800 328 3874 Fax 763 557 1971 ...