- 18 -
Cabinet Pre-Heating (Propane Units)
WARNING: Always wear gloves when adjusting the damper.
The burner exhaust is equipped with an adjustable Thermal Regulating Gate (A) and a damper
(B) to help regulate the amount of heat diverted to the cabinet for hose, wand and plumbing
preheating. At the end of each day after cleaning out the system, the hose should be coiled
and placed in the cabinet. The wand may remain attached as it will fit in the cabinet.
NOTE: On units equipped with a heated hose, the hose and wand must remain out-
side the cabinet.
COLD START-UP
1)
Close the damper until it covers the exhaust stack. Open the gate by lifting lever (C) to
the full open position. This will force hot air into the cabinet. The temperature gauge
installed in the side of the cabinet will measure actual temperature.
Never
allow
cabinet temperature to exceed 320º F. Open the door partially if necessary. Adjust
gate or close completely to keep the temperature below 320º F.
2)
Once the material in the tank has started melting and is circulating through the plumbing
system, open the damper and close the gate. This will prevent excessive cabinet
temperatures and will divert the heat around the oil for more efficient heating.
A
C
B
Содержание 105
Страница 43: ... 43 Hydraulic Schematic B2 A2 A1 B1 MD1 MD2 G2 R2 CS1 093 1500PSI R1 P T Model 105 1100 PSI Model 225 800 PSI ...
Страница 49: ... 49 Wiring Diagrams Complete Wiring Diagram No Heated Hose OilThermocouple Material Thermocouple ...
Страница 67: ... 67 6 11 12 1 7 10 5 3 4 2 13 9 Miscellaneous Parts ...
Страница 70: ... 70 Notes ...
Страница 72: ...2601 Niagara Lane Plymouth MN 55447 763 557 1982 800 328 3874 Fax 763 557 1971 ...