- 15 -
Starting the Engine
NOTE: Read the engine instruction manual before starting.
Propane Engine:
NOTE: Allow oil thermometer (mounted on tank) to reach 250º F. before starting this
procedure.
1)
Place the pump drive (A) and agitation control (B) levers in the neutral (center detent)
position.
2)
Start the engine (Refer to Kohler Engine Manual for start up procedure, maintenance
and trouble shooting).
3)
The prime button (C) on the L.P. regulator will allow fuel to enter the carburetor while de-
pressed. This may be required for cold start up.
4)
The maximum engine RPM stop is factory set at 2500 RPM. The engine should be run
at 2200 to 2500 RPM during use. It will have adequate power to perform all functions at
this setting. Increasing engine speeds will create hydraulic failure and shorten engine
life.
B
C
A
Vaporizer
(optional for
liquid withdrawal applications)
Содержание 105
Страница 43: ... 43 Hydraulic Schematic B2 A2 A1 B1 MD1 MD2 G2 R2 CS1 093 1500PSI R1 P T Model 105 1100 PSI Model 225 800 PSI ...
Страница 49: ... 49 Wiring Diagrams Complete Wiring Diagram No Heated Hose OilThermocouple Material Thermocouple ...
Страница 67: ... 67 6 11 12 1 7 10 5 3 4 2 13 9 Miscellaneous Parts ...