43
Trouble
Shooting
If water flows to drain, check for particles in the Main
Sol V/V
12-5-B. MAIN SOL V/V DEFECT
Symptom
1. Water flows to drain (Main V/V has particles)
2. Water is dripping down from Ice dispense tunnel / rotator blade.
Cause of Defect
If there are particles stuck in the Main Sol V/V, may cause the water to drip down from Ice dis-
pense tunnel / rotator blade.
AS Procedure
1) Detach Main Sol V/V and remove particles.
2) Water may leak from Main Sol V/V, if not reassembled properly.
How to Diagnose
1