Shooting
28
Check to see if Ambient tank is (25%)
full.
(CWLS Mesh/ Medium Filter)
Check to see if water is flowing from
the Post Carbon Filter.
ENSOR DEFECT
Symptom
Water tanks do not get full.
Cause of Defect
1. Mesh clog 2. Defective Pump
3. Defective Sol V/V
4. Membrane clog
AS Procedure
1) If Mesh / Medium Filter are clogged: Clean or replace.
2) Check to see if water is coming out after the Post Carbon Filter.
a. Adaptor
b. Sol V/V
c. Booster Pump
d. Membrane Filter.
How to Diagnose
1
2
3
Cold water operates above (25%).
Check to see if water is purifying properly