CE TEMPERATURE SENSOR
Symptom
1. No Cold water / No Ice, ICE FULL LED blinking.
-Connect Test Board; LED13 starts blinking.
2. If the Ice temp. sensor reaches -22F, it stops making Ice.
Cause of Defect
If Ice temp. sensor detects -22ºF, it will cause Circulation pump to be considered defective and stop
the Comp.
- When sensor is defective or disconnected, system stops making Ice.
How to Diagnose
** The sensor is the same for Iguassu Ice and Ice Combo Plus
Check ohm reading of sensor.
Connect Test Board: If LED13 blinks, then check sensor.