40
Tr
ouble
Shooting
12-3-E. HOT GAS V/V WIRE DISCONNECT
Symptom
Ice is made, but does not fall off the fingers.
Cause of Defect
If Hot Gas does not flow properly, may lead to the Axle Coupling to break.
AS Procedure
1) Check power “ON” or “OFF” from Test Board (LED4).
2) Change Wire or check Wire connection.
How to Diagnose
Connect Test Board and press the Ice Re-
lease Button.
Check to see if it is functioning.
1
2
Voltage : AC 220V