Shooting
32
Connect Test Board : Ice fails to make after 3 tries (avg. 10min/try),
Test Board LED 13 / 22 starts blinking.
G. CIRCULATION PUMP DEFECT
Symptom
1. Water does not circulate if defective; causing Ice Full LED to blink.
- Connect Test Board: Circulation pump defective or Ice tray frozen.
2. If Ice tray is frozen; may cause Camshaft axle coupling to break.
Cause of Defect
Defective Circulation Pump will cause over-freezing, thus may cause the Axle coupling to break.
AS Procedure
1) Replace Camshaft axle coupling.
2) Replace Circulation pump if necessary.
3) Check to see if water in the water tray is frozen or melted.
- If frozen, it may take at least
6 hours
to melt.
How to Diagnose