Restoring the default factory setting:
By clicking
you can overwrite the current setting with the setting used for the
commissioning of the camera at the Chromasens production facility. This only affects the
currently active setting.
Obtaining camera information:
To obtain camera information, click
Display camera information
. The following
dialog box is shown:
If there are any problems with the camera or the parameter settings, it is very helpful for the
Chromasens support to obtain the camera information.
To add this information to an email to Chromasens support, click
Copy to clipboard
and paste
the information into your email.
10.2 Performing a white balancing on the camera
You can perform white balancing automatically (see section 10.2.1) or manually (see section
10.2.2)
Setting the operation point automatically
NOTE
The position of the white reference mark (control zone) and the target gain
value for the control zone are used as saved in the setting.
This operation only takes place in the currently selected setting.
This function has to receive line data inside the camera. If the camera is
set to line trigger or encoder mode and the transport is not moving, an error
occurs.
Set the camera to internal line trigger.