
CD40047_R04_allPIXA_User-Manual.docx
119
Creating a white (gain) reference internally
The creation of shading reference is only necessary during commissioning or if the gain values
are changed considerably.
1
Get the camera to the desired working point
Place a white reference in front of the camera
Check the lighting and focusing
Disable continuous white control
Save the parameters to the camera
Optional:
Activate black-level correction
Optional:
Perform white-balancing
Note:
The white reference target must be placed in the best focus plane of the camera.
Therefore any features on its surface (for example dust, scratches) end up in the calibration
profile of the camera. To avoid this if you use a static (non-moving) white reference target,
use a clean white ceramic or plastic material, not paper. Ideally, the white object should move
during the calibration process because the movement results in an averaging process and
the camera diminishes the effects on any small variation in the white reference.
2
Start the reference wizard, and select reference type and image source
On the toolbar, click
Start reference wizard
.
Click
White (flat-field) level reference
.
Click
Create reference internally
:
Click
Next
.
Содержание allPIXA
Страница 1: ...allPIXA camera Manual CD40067 R04 2018 07 12...
Страница 7: ...CD40047_R04_allPIXA_User Manual docx 7...
Страница 106: ...CD40047_R04_allPIXA_User Manual docx 106...
Страница 198: ...CD40047_R04_allPIXA_User Manual docx 198 15 EC conformity declaration...