CD40047_R04_allPIXA_User-Manual.docx
191
Line trigger / encoder reduction
Name
Name
Line trigger/encoder reduction
Function
Internal pre-counter for the line trigger or encoder signal, outputs an internal
line trigger after the specified value of signals from external line trigger source.
Channels
All
Unit
integer
Dependency
Only available if
Enable encoder
is selected.
Notes
Camera
Value
Lower limit
All
1
Upper limit
All
256
If line trigger reduction is used, the vertical image resolution is reduced by factor:
𝑇𝑟𝑎𝑛𝑠𝑝𝑜𝑟𝑡𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛, 𝑟𝑒𝑑𝑢𝑐𝑒𝑑[𝑑𝑝𝑖] =
𝑇𝑟𝑎𝑛𝑠𝑝𝑜𝑟𝑡𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛[𝑑𝑝𝑖]
Line trigger reduction factor
𝑇𝑟𝑎𝑛𝑠𝑝𝑜𝑟𝑡𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛, 𝑟𝑒𝑑𝑢𝑐𝑒𝑑[µ𝑚] = Line trigger reduction factor ∗ 𝑇𝑟𝑎𝑛𝑠𝑝𝑜𝑟𝑡𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛[µ𝑚]