CD40047_R04_allPIXA_User-Manual.docx
33
5.2 Power supply
Take notice that the following connector is required for the power supply cable:
Manufacturer:
Hirose
Article no.:
HR10A-7P-
6S “female” (male connector is located on the camera)
Pin no.
Description
1
Power +24 V
2
Power +24 V
3
Not connected
4
Not connected
5
Ground
6
Ground
For more information about the input voltage and currents, see section 2.2
5.3 Config UART (serial RS 232)
Serial connection to the PC can be established by using a 9-pin D-Sub connector (male) via the
interface of serial RS 232 (V24).
Pin no.
Description
1
Not connected
2
Transmit data
3
Receive data
4
Data terminal ready
5
Ground
6
Not connected
7
Request to send
8
Not connected
9
Not connected