CD40047_R04_allPIXA_User-Manual.docx
87
Setting the operation point manually
Manual operating point setting serves to determine the area which is viewed by the allPIXA
camera for carrying out the shading correction.
The pattern below describes the principle of analog image processing.
Figure 33 Analog image processing comprises of two levels.
1) Analog coarse gain: Pre-Amplification factor
For rough adjustment of the sensor signal to the main amplifying level.
2) Current camera gain values: Main analog amplifying level
For fine-adjustment of analog gaining.
For more information about camera gain adjustment, see section 11.2.
NOTE
Manual operating point setting is carried out during commission by using a
shading reference for the operating point.
1
Setup
Set the camera to free-running mode(disable encoder and or frame trigger).
Use a white balancing reference that covers the entire scanning range.
Figure 32: allPIXA camera with a white balancing reference
Check the alignment of the illumination and the allPIXA camera by using a suitable
viewer (for example the line plot display of your frame grabber software).
Figure 32: Line plot display