Appendix A: Serial API Commands
CP2210 User Manual
A-9
020-100410-07 Rev. 1 (01-2012)
Lamp Intensity Calibration (LCA)
This control is used to calibrate (correlate) the intensity feedback mechanism to footlamberts. Note the minimum/
maximum power are used to pick two points on the curve. These points will not stay consistent over the life of the
lamp, but the conversion algorithm will extrapolate the conversion beyond the range of the two end points. Foot-
lamberts for minimum/maximum power are converted to integer by multiplying 100 because serial command pro-
tocol does not support floating point number.
NOTE
:
Changing the lamp or lamp alignment will require re-
calibration.
SUBCODE
DESCRIPTION OF USE
MAXF
Set footlamberts at maximum lamp power, the value should be (footlamberts * 100)
MAXS
Set sensor value at maximum lamp power
MINF
Set footlamberts at minimum lamp power, the value should be (footlamberts * 100)
MINS
Set sensor value at minimum lamp power
NONE
Not available
EXAMPLES:
(LCA+MINF 10) Set 10 footlamberts as measured brightness at minimum lamp power
(LCA+MINF?) Get footlamberts on minimum lamp power
(LCA+MINS 5000) Set 5000 as reading value from the light sensor at minimum lamp power
(LCA+MAXF 17) Set 17 footlamberts as measured brightness as maximum lamp power
(LCA+MAXF?) Get footlamberts at maximum lamp power
(LCA+MAXS 15000) Set 15000 as reading value from the light sensor on maximum lamp power
LUT CLUT Control (LCT)
Set Look up Table (LUT) Color Look Up Table (CLUT) file for the specified channel. The CLUT is used during
color processing in the cinema electronics.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid range is 101 - 164.
NONE
Select CUT for the current channel.
EXAMPLES:
(LCT+C108 “9x9x9”) Use PCF file “9x9x9” on channel 108
(LCT+C108?) Get LUT-CLUT file name on channel 108
(LCT?L) List all entries of LUT-CLUT control
Link Decrypter Bypass (LDB)
Setting LD bypass to TRUE (1) will bypass the link decrypter (LD). Only use if marriage is broken and content being played is
not CineLink 2 encrypted (non D-Cinema content).
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid range is 101 - 164.
NONE
Set to 1 to bypass and 0 to not bypass.
EXAMPLES:
(LDB+C108 1) Bypass link decrypter on channel 108.
(LCT 0) Use link decrypter on current channel (i.e. do not bypass).
(LCT+C108?) Get value for LDB on channel 108.
Содержание Solaria CP2210
Страница 1: ...CP2210 U s e r M a n u a l 020 100410 07 ...
Страница 2: ......
Страница 3: ...CP2210 U S E R M A N U A L 020 100410 07 ...
Страница 10: ......
Страница 14: ......
Страница 26: ......
Страница 32: ......
Страница 48: ......
Страница 100: ...6 46 CP2210 User Manual 020 100410 07 Rev 1 01 2012 Section 6 Projector Menus Figure 6 39 Add a New User Window ...
Страница 110: ......
Страница 120: ......
Страница 126: ......
Страница 152: ......
Страница 163: ... 000 101833 07 ASSY TECH DOCS CP2210 ...